Technical Library: removing module without power (Page 1 of 1)

What is an analog signature analyzer and how does it work?

Technical Library | 2020-11-19 20:35:26.0

Simultaneously with the first complex electronic circuits, the task of creating effective means of diagnosing and repairing them appeared. In previous decades, specialized programmable stands were used for diagnostics of serial electronic products, as well as various testers and probes for troubleshooting during their operation. But the dramatic increase in the density / cost factor, in parallel with the very rapid modification of electronic products, made programmable stands economically ineffective even in mass production. The use of traditional laboratory equipment (oscilloscopes, multimeters, etc.) requires power supply to the defective modules, which is often impossible and unsafe, since it can lead to failure of the working modules of the module. In addition, the use of this equipment requires documentation and highly qualified personnel. More automated and sophisticated signature analysis systems came to the rescue in solving this problem. A feature of these devices is that they allow you to test digital and analog assemblies without dismantling components and without supplying voltage.

Engineering Physics Center of MSU

Dust removal in temperature and humidity Test Chamber (2/2)

Technical Library | 2019-05-21 00:21:26.0

Continue to talk about the dust removal from temperature humidity test chamber. Cleaning and maintenance: 1) Pls remove internal impurities inisde chamber before operation. 2) The power distribution room should be cleaned at least once a year, and the dust can be removed by vacuum cleaner. 3) The exterior chamber must also be cleaned more than once a year, which can be wiped with soapy water. Inspection and maintenance of humidifier: The water storage in humidifier should be replaced once a month to ensure clean water quality, humidifying water tray should be cleaned once a month to ensure smooth flow of water. The inspection of over-temperature protector:during the test: If the temperature is over 20 ℃ ~ 30 ℃ than the maximum value setted,the power supply of the heater will stop, the "OVERHEAT" overt-emperature warning light will automatically turn on but the fan is still in operation, if the equipment runs without operator around,the operator should check the over-temperature protector in advance to ensure wether it has been setted properly before start [wet ball over-temperature protector set to 120 ℃].

Symor Instrument Equipment Co.,Ltd

Heat Sink Induced Thermomechanical Joint Strain in QFN Devices

Technical Library | 2024-07-24 00:51:44.0

A blade server system (BSS) utilizes voltage regulator modules (VRMs), in the form of quad flat no-lead (QFN) devices, to provide power distribution to various components on the system board. Depending on the power requirements of the circuit, these VRMs can be mounted as single devices or banked together. In addition, the power density of the VRM can be high enough to warrant heat dissipation through the use of a heat sink. Typically, at field conditions (FCs), the BSS are powered on and off up to four times per day, with their ambient temperature cycling between 258C and 808C. This cyclical temperature gradient drives inelastic strain in the solder joints due to the coefficient of thermal expansion (CTE) mismatch between the QFN and the circuit card. In addition, the heat sink, coupled with the QFN and the circuit card, can induce additional inelastic solder joint strain, resulting in early solder joint fatigue failure. To understand the effect of the heat sink mounting, a FEM (finite element model of four QFNs mounted to a BSS circuit card was developed. The model was exercised to calculate the maximum strain energy in a critical joint due to cyclic strain, and the results were compared for a QFN with and without a heat sink. It was determined that the presence of the heat sink did contribute to higher strain energy and therefore could lead to earlier joint failure. Although the presence of the heat sink is required, careful design of the mounting should be employed to provide lateral slip, essentially decoupling the heat sink from the QFN joint strain. Details of the modeling and results, along with DIC (digital image correlation) measurements of heat sink lateral slip, are presented.

IBM Corporation

Noise Fault Detection of High Low Temperature Test Chamber(Climatic chamber)

Technical Library | 2019-04-11 06:04:49.0

With the development of science and technology, the climatic chamber quality has been improved, and the failure rate is reduced, but there still have the failure probability.today we introduce what are the mian factors for big noise high low temperature test chamber: 1.External factors: the bottom angle is uneven, the ground is uneven, adjust the bottom angle, ensure the equipment is in a horizontal position; 2.The equipment is touched other objects or pushed against the wall,pls remove the objects and keep a certain distance from the wall. 3.Compressor noise:check whether the compressor collides with the pipeline,and evaporator dish is loose or not. 4.Check whether compressor shock absorbers are aging and replace them. 5.Solenoid valve noise: solenoid valve reversing caue loud sound, pls add damping glue, if no effect, need to replace solenoid valve. If there is AC noise, need to replace the power board. 6.Check wether the fan or the fan string shaft make noise,whether the fan blades are touched and deformed, whether the fan is fixed or not, pls adjust accordingly or add the rubber pad. If further technical questions,contact us without hesitation!---Climtest Symor® technical team

Symor Instrument Equipment Co.,Ltd

  1  

removing module without power searches for Companies, Equipment, Machines, Suppliers & Information