Industry Directory | Manufacturer
ASLi main products: Temperature (humidity) chamber, Thermal Shock Test Chamber, Sand and Dust Tester , Rain Spray Tester, UV Chamber, Ozone Chamber, Xenon Climate Chamber , Salt Spray Corrosion Chamber, High Temperature (Vacuum )
Industry Directory | Manufacturer
environmental test chamber manufacturers and vibration test system suppliers. Including climate test chamber, thermal shock test chamber, stability test chamber, ESS chamber, walk-in test chamber, altitude test chamber,
Dual Chamber Module - Dual Chambers + Dual Blowers + Dual Heaters + Dual T/Cs. Bifurcated (Dual) chamber reflow oven allows 2 different thermal profiles to run simultaneously in the same reflow oven foot print Improved temperature uniformity acro
As part of our commitment to being a Solutions Provider, Saline Lectronics also offers extensive testing services related to your circuit board assembly products. In addition to supporting each of the different types of testing requirements includin
Electronics Forum | Wed Jul 20 01:44:51 EDT 2005 | Ron
Hello!! Where can I find some materials and information about temperature testing?? We have a new temperature testing chamber and i would like to know how fast product will cool down and after that how soon can I put this product to high temperature
Electronics Forum | Thu Dec 07 15:51:02 EST 2000 | gsubbert
We have an old Blue M temperature chamber. We have no manuals for it and no information on how to make the cams to get the temperature profile that we need. If anyone has any information and would be willing to share it with me I would appreciate it.
Used SMT Equipment | In-Circuit Testers
1988 Thermotron FA-4-CH-1-1 Environmental Chamber Temperature Range: -73C to 177C (-99F to 351F) Control Accuracy: 1.0+/- C Internal Dimensions: 20" x 20" x 20" External Dimensions: 32" x 34" x 82" Power: 208VAC; 28A; 60Hz; 3 Phase Serial: 165
Used SMT Equipment | General Purpose Equipment
Tenney - Blue M Thermal Shock Chamber For Sale See attached pictures and information below Equipment Information Tenney - Blue M - TPS Model Number: WSP-109 Serial Number: 0801000082 Year: 2007 Type: Hot Cold - Shock
Industry News | 2003-06-25 12:28:40.0
The chart includes a variety of diagrams, tables, and ratio charts for RF Emissions; Direct RF Power Injection; Bulk Current Injection (BCI); ESD and Transients; as well as TEM Cell and Stripline testing.
Industry News | 2014-05-22 15:42:29.0
Baja Bid announces their next online auction. This event includes assets from OneChip Photonics in Kanata, Ontario Canada.
Parts & Supplies | SMT Equipment
Original Smt spare parts JUKI 40053181 775 TEMPERATURE BLIND CONTROLLER HD00176000 JUKI Nozzle Specifications: Brand Name JUKI TEMPERATURE BLIND CONTROLLER Part Number 40053181 Model Number HD00176000 Ensure Tested buy juki Guarantee 1 mont
Parts & Supplies | Soldering - Reflow
This reflow oven is top quality oven represent the world's best low cost, high performance solder reflow sytem. The sensor is designed in the front of tip and the temperature induction is very exact and sensitive, the speed of heating and recovery of
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Technical Library | 2019-11-17 22:46:45.0
Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers
Events Calendar | Wed Apr 19 00:00:00 EDT 2017 - Fri Apr 21 00:00:00 EDT 2017 | Nara, Japan
Ceramic Interconnect and Ceramic Microsystems Technologies (CICMT 2017)
International Microelectronics Assembly and Packaging Society (IMAPS)
Career Center | San Diego, California USA | Sales/Marketing,Technical Support
Do you want to put your dent in the universe? Are you are tired of being part of a slow moving bureaucratic coatings organization that sells old technology, can’t get things done and seems to create processes to hinder the selling process? Are y
Career Center | Bangalore, India | Engineering,Management,Production,Quality Control,Technical Support
WORK EXPERIENCE DETAILS: 7+ Years of Experience in manufacturing & hardware testing of Protocol conveter & Commissioning, Products delivery and QA/QC. 2+ Years of Experience in Hardware testing and Package Level testing. 2+ Years of Experience in
Article Return to Front Page A Low Temperature Alte
Article Return to Front Page A Low Temperature Alte
Lewis & Clark | http://www.lewis-clark.com/product/ransco-7210-2-temperature-cycling-chamber/
Ransco 7210-2 Temperature Cycling Chamber - Lewis and Clark Skip to content My Cart: 0 View Cart Checkout No products in the cart. Subtotal
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/industrial-coating-systems/additional-product-sub-type/temperature-conditioning?con=t&page=7
: Temperature Conditioning Model A7A Color-Change Valves Industrial Coating Systems Single or dual-chamber automatic spray guns for versatile, reliable high-production airless