Technical Library: alarm (Page 1 of 1)

What causes temperature humidity chamber to alarm?

Technical Library | 2019-12-12 02:43:44.0

Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.

Symor Instrument Equipment Co.,Ltd

How to choose a reliable CF Card for VDR

Technical Library | 2018-11-22 05:21:52.0

VDR (Voyage Data Recorder) is an instrument continuously recording real-time data of ship body, including speech communication signal of cockpit, sensors data, alarm status and radar images, etc.. So what's types of storage devices may meet VDR's requirement?

Renice Technology Co., Ltd

Orbotech Trion 2340 Manual

Technical Library | 2020-10-30 10:27:39.0

Preview of the Complete Aneryn's Orbotech Trion 2340 Manual. It explains how to programme the AOI machine, how to train new components (shapes), how to connect it to your network, among other processes. Following the Guide, you will minimize false alarms and escapes rates easily. Full Manual available at https://aneryn.com/creation/trion-2340-manual/ Digital development by Sinfonía Digital

Aneryn

Advanced Physical Inspection Methods for Counterfeit IC Detection

Technical Library | 2021-10-12 18:05:09.0

The remarkable increase in counterfeit parts (a factor of 4 since 2009) [1] is a huge reliability and security concern in various industries ranging from automotive electronics to sensitive military applications increasing the possibility of premature failure in critical systems [2-5]. Counterfeit parts can also incur a great financial loss to legitimate electronics companies [6]. The issue is even more alarming as the counterfeiters use more sophisticated methods making counterfeit detection a much harder task [7-8]. Therefore, it is reasonable to develop more advanced counterfeit detection methods targeting a more efficient detection of sophisticated counterfeited parts.

University of Connecticut

Causes and Costs of No Fault Found Events

Technical Library | 2016-04-14 13:49:44.0

A system level test, usually built-in test (BIT), determines that one or more subsystems are faulty. These subsystems sent to the depot or factory repair facility, called units under test (UUTs) often pass that test, an event we call No-Fault-Found (NFF). With more-and more electronics monitored by BIT, it is more likely that an intermittent glitch will trigger a call for a maintenance action resulting in NFF. NFFs are often confused with false alarm (FA), cannot duplicate (CNDs)or retest OK (RTOK) events. NFFs at the depot are caused by FAs, CNDs, RTOKs as well as a number of other complications. Attempting to repair NFF scan waste precious resources, compromise confidence in the product, create customer dissatisfaction, and the repair quality remains a mystery. The problem is compounded by previous work showing that most failure indications calling for repair action at the system level are invalid. NFFs can be caused by real failures or may be a result of system level false alarms. Understanding the cause of the problem may help us distinguish between units under test (UUTs) that we can repair and those that we cannot. In calculating the true cost of repair we must account for wasted effort in attempting to repair unrepairable UUTs.This paper will shed some light on this trade-off. Finally, we will explore approaches for dealing with the NFF issue in a cost effective manner.

A.T.E. Solutions, Inc.

Serious to make dry oven

Technical Library | 2019-11-13 02:09:44.0

Dry oven is a must instrument almost for every laboratory in different industries,with nearly 20 years efforts and innovation,Climatest now masters core technique of dry oven manufacturing,no matter on temperature uniformity or temperature stability.Behind the quality is 15 years of consistent persistence,strong belief in excellence; from design to R & D to production, from promotion to sales to installation; every step should reach excellence,What you see, you use our products, you choose, you feel that we do our best,this is our faith. Dry Ovens are used to dry or temper electronic components,material tests,torrefaction, wax-melting ,high temperature aging ,preheating and sterilization in industrial and mining enterprises, laboratories and scientific research institutes. .Exterior chamber is made by reinforced steel with painting; working chamber made by anti-corrosion stainless steel SUS#304 .Intelligent PID control, LED controller with over-temperature alarm,timing range within 0~9999min .Hot air circulation system composed of Germany imported low-noisy air blower and optimal air duct which ensure uniform temperature distribution .Double layers of glass door, large transparent window to observe specimen .Forced air convection Climatest manufactures desktop and floor-standing models with RT+10°C-200°C,250°C,300°C,350°C,400°C temperature range,and customized as per special requirement,if you wanna know more details about our dry oven,please visit our product page:https://climatechambers.com/industrial-dry-oven/200-degree-c-hot-air-oven.html

Symor Instrument Equipment Co.,Ltd

  1  

alarm searches for Companies, Equipment, Machines, Suppliers & Information