Industry Directory | Consultant / Service Provider / Manufacturer
Gen3 Systems is a specialist manufacturer of test and measurement equipment used to help predict reliability of electronic circuits and systems in the field.
Industry Directory | Manufacturer's Representative
Electronics Swab Sticks, Fibre Optic Cleaning Swabs, Foam Swab, ESD Swab, Polyester Swab, Cleanroom & ESD swabs, dry wiper, sticky mats, cleanroom consumable, cleanroom supplier
New Equipment | Cleaning Equipment
PCB Surface Cleaning Machine MLPCM-450 Technical Parameters 1. Independent innovation patent design (patent: 2017SR471774), the industry's first, lets you have the most advanced contact cleaning system in the industry. 2. Using Panasonic PLC program
New Equipment | Cleaning Equipment
PCB Surface Cleaning Machine SMM-450 Feature Improve quality ▶ Abnormal quality due to dust ▶The product is unqualified due to residual static electricity Improve efficiency ▶Improve printing quality ▶Improve SPI pass-through rate ▶Improve AOI pass-
Electronics Forum | Thu Oct 08 12:02:15 EDT 1998 | Bernardo Mendoza
I need to set a cleanliness limit for our incoming boards. I know that some people use 14-10 microgr. sq. in. But how can I determine what is best for me. Can anybody tell me if there's a standard for this. Right now we are using an Alpha Ionograph
Electronics Forum | Fri Oct 09 14:29:07 EDT 1998 | Chrys
| I need to set a cleanliness limit for our incoming boards. I know that some people use 14-10 microgr. sq. in. But how can I determine what is best for me. | Can anybody tell me if there's a standard for this. | Right now we are using an Alpha Iono
Industry News | 2021-05-25 12:56:56.0
The SMTA Officer team is excited to provide our members with a free technical webinar on "The Relationship Between Cleanliness and Reliability/Durability" by Debbie Carboni, Global Product Manager at KYZEN Corporation. The presentation will take place on June 10th at 11:00am EST and include:
Industry News | 2018-09-23 09:57:15.0
Industry-leading associations IPC and SMTA jointly announce the High-Reliability Cleaning and Conformal Coating Conference, scheduled to take place November 13-15, 2018 at Chicago Marriott, Schaumburg, Illinois. The conference is focused on the cleanliness of highly dense electronic assemblies to achieve quality and reliability within the stated in-field environment.
Technical Library | 2019-08-01 10:58:32.0
Optical fibers transmit information in the form of pulses of light. The advantages of optical fibers over traditional copper wires include: higher throughput, greater signal distance and speed, smaller cable mass and diameter, greater pull tension limit, and resistance to electromagnetic interference (EMI) and radio frequency interference(RFI). The disadvantages of fiber optics when compared to copper wires include: end-face defects, cleanliness, and the ease of attaching connectors to electronics assemblies (Figure 1).
Technical Library | 2023-04-17 21:17:59.0
The purpose of this paper is to evaluate and compare the effectiveness and sensitivity of different cleanliness verification tests for post soldered printed circuit board assemblies (PCBAs) to provide an understanding of current industry practice for ionic contamination detection limits. Design/methodology/approach – PCBAs were subjected to different flux residue cleaning dwell times and cleanliness levels were verified with resistivity of solvent extract, critical cleanliness control (C3) test, and ion chromatography analyses to provide results capable of differentiating different sensitivity levels for each test. Findings – This study provides an understanding of current industry practice for ionic contamination detection using verification tests with different detection sensitivity levels. Some of the available cleanliness monitoring systems, particularly at critical areas of circuitry that are prone to product failure and residue entrapment, may have been overlooked. Research limitations/implications – Only Sn/Pb, clean type flux residue was evaluated. Thus, the current study was not an all encompassing project that is representative of other chemistry-based flux residues. Practical implications – The paper provides a reference that can be used to determine the most suitable and effective verification test for the detection of ionic contamination on PCBAs. Originality/value – Flux residue-related problems have long existed in the industry. The findings presented in this paper give a basic understanding to PCBA manufacturers when they are trying to choose the most suitable and effective verification test for the detection of ionic contamination on their products. Hence, the negative impact of flux residue on the respective product's long-term reliability and performance can be minimized and monitored effectively.
PCB Surface Cleaning Machine MLPCM-450 Technical Parameters 1. Independent innovation patent design (patent: 2017SR471774), the industry's first, lets you have the most advanced contact cleaning system in the industry. 2. Using Panasonic PLC program
See the Nu/Clean Aqua Batch Aqueous Batch Cleaner in operation! Quick, quiet, close loop cleaning at a great price! For technical specifications, visit our website www.TechnicalDev.com.
Training Courses | ONLINE | | PCB Assembly Courses
The PCB assembly courses provide knowledge of different processes and equipment used in TH and SMT assembly of printed circuit boards.
Events Calendar | Mon May 10 00:00:00 EDT 2021 - Mon May 10 00:00:00 EDT 2021 | ,
Europe Chapter Webinar: Manual Cleaning of Printed Board Assemblies – Step by Step Guide
Career Center | Milpitas, California USA | Production,Quality Control
Winslow Automation, Inc. (aka Six Sigma), an industry leader in electronic component interconnect technology & related test and failure analysis services, is seeking an experienced, detail-oriented, quality-conscious team player for our Quality Assur
Career Center | Milpitas, California USA | Engineering,Production,Quality Control,Research and Development,Technical Support
Winslow Automation, Inc. (aka Six Sigma), an industry leader in electronic component interconnect technology & related test and failure analysis services, is seeking individuals specializing in materials lab testing to join our team. We have openin
| https://www.eptac.com/faqs/ask-helena-leo/ask/ipc-5704-vs-ipc-6012-bare-board-cleanliness-comparison
: I am reviewing IPC-5704, and have a question. When reviewing table 4-1, the chloride limit is 0.75 ug/cm2, which converts to 4.4 ug/in2, however; IPC 6012 still has the board cleanliness limit for sodium chloride as
| https://ipcapexexpo.org/plan-to-proceed
. Our team is committed to upholding the highest standards of cleanliness throughout our facility. Considering the dramatic changes to public health guidance due to the COVID-19 pandemic, we have updated or enhanced many of our cleaning and safety protocols to help ensure the safety and security