Technical Library: wetting problem (Page 1 of 1)

Humitector™ Type 2 Non-Reversible Humidity Indicator Cards from Clariant help assure the integrity of moisture-sensitive surface-mount devices

Technical Library | 2021-02-20 00:55:47.0

Customers must be able to rely on accurate humidity indication as an assurance of SMD quality and fitness for processing and use. Without it, they might accept SMDs from suppliers that have already been irreparably damaged by moisture during storage or transit. Or, they might approve for processing SMDs that have been improperly or insufficiently heat-dried. Beyond the processing questions, there are financial questions: Where did the dry pack problems originate and who--supplier, customer, shipper--is financially responsible for the damaged SMDs? In response, Clariant, the originator of the color change humidity indicator card, and a member of the JEDEC's Subcommittee 14.1, "Reliability and Test Methods for Packaged Devices," created a new "non-reversible" halogen and cobalt dichloride free humidity indicator card. This HIC combines two reversible indicators (5% and 10%) with a new non-reversible (60% RH) indicator spot. (Figure 1) The 5% and 10% reversible spots work the way similar indicators do: they change color from blue (dry), to lavender, to pink (wet) to indicate humidity exposure at the indicated levels. If humidity levels drop, they will gradually revert back to blue.

Clariant Cargo & Device Protection

A Case Study in Troubleshooting Shop Floor Rework Difficulties

Technical Library | 2007-04-05 13:48:50.0

Recently a large global player approached us with a problem. They needed an initial assembly solution for brand new components. Their boards and CSP specimens could not safely be soldered due to wetting problems at the solder joints.

MARTIN (a Finetech company)

The Effect Of Metallic Impurities On The Wetting Properties Of Solder

Technical Library | 1999-05-07 10:38:11.0

This paper is a report of a study made to determine the maximum allowable impurities in solder used for wave soldering applications. This report concludes with a list of impurities compiled from actual analyses of solder which caused production problems. A list of recommended maximum allowable impurities will assist in establishing reliable quality controls on the purity level of the solder in a wave soldering machine.

Kester

Solving the ENIG Black Pad Problem: An ITRI Report on Round 2

Technical Library | 2013-01-17 15:37:21.0

A problem exists with electroless nickel / immersion gold (ENIG) surface finish on some pads, on some boards, that causes the solder joint to separate from the nickel surface, causing an open. The solder has wet and dissolved the gold. A weak tin to nickel intermetallic bond initially occurs, but the intermetallic bond cracks and separates when put under stress. Since the electroless nickel / immersion gold finish performs satisfactory in most applications, there had to be some area within the current chemistry process window that was satisfactory. The problem has been described as a 'BGA Black Pad Problem' or by HP as an 'Interfacial Fracture of BGA Packages…'[1]. A 24 variable experiment using three different chemistries was conducted during the ITRI (Interconnect Technology Research Institute) ENIG Project, Round 1, to investigate what process parameters of the chemical matrix were potentially satisfactory to use and which process parameters of the chemical matrix need to be avoided. The ITRI ENIG Project has completed Round 1 of testing and is now in the process of Round 2 TV (Test Vehicle) build.

Celestica Corporation

Maintenance and operation of walk-in temperature humidity test chamber

Technical Library | 2019-11-17 22:46:45.0

Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers

Symor Instrument Equipment Co.,Ltd

  1  

wetting problem searches for Companies, Equipment, Machines, Suppliers & Information

Equipment Auction - Eagle Comtronics: Low-Use Electronic Assembly & Machining Facility 2019 Europlacer iineo + Placement Machine  Test & Inspection: Agilent | Tektronix | Mantis Machine Shop: Haas VF3 | Haas SL-20 | Mult. Lathes

World's Best Reflow Oven Customizable for Unique Applications
Electronics Equipment Consignment

High Resolution Fast Speed Industrial Cameras.
Selective soldering solutions with Jade soldering machine

High Throughput Reflow Oven