Electronics Forum | Thu Nov 17 17:44:19 EST 2011 | bobpan
Tim, 1. You dont need the vacuum verify if the quadalign is working properly. If you have the part quad-aligned and dont have alignment type at 0 it will never 'not' place a part. More or less...the vac verify was needed for the chucking machine (3c)