Electronics Forum | Fri Jan 21 05:39:58 EST 2000 | Scott Davies
Hi ZJJ, I know exactly where you're coming from on this one! We have a similar situation here with a SiPlace 80S-15, rated at 15K max per hour. In practice, we achieve about 11K. The reason is fairly straightforward. The quoted maximum placements pe
Electronics Forum | Fri Jan 21 19:27:54 EST 2000 | Scott S. Snider
With the Siemens line computer it is possible to see what the maximum placements per hours should be for any given job/setup. After you optimize the job you should check that and see how you perform against that number. In many cases the placements
Electronics Forum | Fri Mar 02 14:28:08 EST 2007 | stimpk
Chris, Can you boot in SiTest?
Electronics Forum | Wed Feb 28 14:01:15 EST 2007 | john_smith
Chris, Is there a job scheduled down to the machine? If you don't have it you can call Siemens hotline @1-888-smt-help. They will talk you through any problems that you encounter. John
Electronics Forum | Sat Mar 03 10:42:49 EST 2007 | chrisgriffin
No. The Sitest button is greyed out. Can I install a regular windows version of NT 4.0, or does it have to be a Siemens version of windows?
Electronics Forum | Fri Feb 23 09:29:59 EST 2007 | chrisgriffin
I did restore the .ma files, and yes, the computer does communicate with the gantries for zeroing. But the machine is still hung on "initializing machine". It never asks me to push the start button. It is like it is trying to collect necessary dat
Electronics Forum | Tue Mar 13 02:12:04 EDT 2007 | (- -")
You have to install the RMOS to MC's HDD. The RMOS Version must match with the station software. After Install RMOS you have to perform machine distribution.
Electronics Forum | Tue Mar 13 13:06:49 EDT 2007 | tommyttr
I think it is in the ideal.ma or actual.ma file. You could also use the first RMOS boot disk. This will ask you for it there.
Electronics Forum | Thu Feb 22 14:41:31 EST 2007 | Tom B
Chris, It's been a while since I used a Siemens, but I was thinking its starting communication to Gantries, tables, and WPC for Axis zeroing. Like I said its been awhile! When replacing drive, did you copy the *.ma files back to the drive? Tom
Electronics Forum | Wed Feb 21 14:56:09 EST 2007 | chrisgriffin
I just had to replace the hard drive in the SC and the MC. I partitiones the MC drive and installed all operating systems. The machine boots up and gets past "software booting", "conversion of machine data", and then hangs on "initializing machine"