HS180 AIR REQUIREMENT

Electronics Forum | Mon Jan 05 14:10:02 EST 2004 | jasper

8 bar, little consupmtion of air. Any compressor will do. No oil. But dry air. Ciao Jasper

BGA using Siemens HS180

Electronics Forum | Thu Dec 06 18:23:01 EST 2001 | stefwitt

It has been done and I could set you up with some customers, who continue to place BGA's on the HS 180 successfully. In the GF editor you define the component as if it had leads around the perimeter. At the end of the editor you activate outline meas

BGA using Siemens HS180

Electronics Forum | Fri Dec 07 00:14:20 EST 2001 | Ivan R

Marcos ,, We do place BGA in our HS180 but not that often , as we do run into some problems sometimes . We found out the best way for us ,, to turn outline on , and also paint the outside of the BGA with white pen and you won`t have any problems .

Siemens SP-120 w/o line computer?

Electronics Forum | Thu Apr 21 12:48:23 EDT 2005 | imserv

I have a Siemens SP-120 and an HS-180 available. Can the SP-120 be used without a line computer installed? Possibly using the HS-180 computer? We are looking to use the machine for short production runs and prototying. Thanks in advance for an

looking for the manual of Siemens HS180,SP120 and line computer

Electronics Forum | Sun Dec 11 09:14:45 EST 2005 | andrew1007

Dear sir, I am a SMT engineer from China. I have diffculty in programming and maintenance of Siemens HS180,SP120.Can u send me some manual for the type of SMT machine.Thank you very much. my e-mail box is andrew1007@hotmail.com Regards!

0603 & Siemens SP120

Electronics Forum | Wed Aug 14 11:04:50 EDT 2002 | pdt203

So what is the trick to placing 0603s on a Siemens SP120? Skip it and run the parts on the HS180? Thanks in Advance, Johnny

Problem with Siemens HS180

Electronics Forum | Wed Nov 12 19:45:33 EST 2003 | juan_ruiz

Siemens has a web site where you may have a better answer to your question. www.siplace.com Regards!

Problem with Siemens HS180

Electronics Forum | Mon Nov 24 07:26:58 EST 2003 | stefwitt

Press shift and clear line. You will be asked for the password. Dependent on software version it is either geheim or mirror. After Password entry, you should be able to edit config and machine data.

HS180 AIR REQUIREMENT

Electronics Forum | Tue Jan 06 08:05:33 EST 2004 | stefwitt

The manual is a bit more specific: Connections and Energy Requirements Specification for the Compressed Air For the compressed air supplied for the automatic placement systems HS-180 (adhesive application station as well as placement station) and SP

Siemens SP-120 w/o line computer?

Electronics Forum | Fri Apr 22 07:22:03 EDT 2005 | Gene

Unfortunately the answer is no. These machines could not be run without line computer because the station computer does not have a program control software, it has the hardware station control only. Computers for SP-120 and HS -180 are the same but