Electronics Forum | Thu May 02 09:08:13 EDT 2002 | darryl
I have a Quad QSP-2 for 5 years and I have had no problems with it. We run it 16 hours per day 6 days a week. Software is good. Service is excellent Quadcare is expensive. The only drawback that I see is tapefeeder repeatability. Seems that the p
Electronics Forum | Mon Apr 24 07:37:57 EDT 2006 | craig_83
We have the IQ system. The problem that I was having is that when I load one board to the other, I want to avoid the table top changeovers. So I figure if I can make certain tabletops to run certain boards the changeovers would be much less. I though
Electronics Forum | Tue Aug 10 15:21:46 EDT 2010 | tanderson
I'm having problems with Quad QSP-2 pick n place machines recognizing fiducials. We are cleaning the fiducials, but that's tedious and time consuming ( I don't know anyone who routinely cleans them). We have solder mask clearance around the fiducials
Electronics Forum | Thu Jun 06 09:03:48 EDT 2019 | bobpan
If the part is 10mm or less as long as you are scanning it near the top...it should work. The other possible problem is dirt on the quadalign lens. Clean off the lens and watch it when it homes....both heads should home the same way. If the head jum
Electronics Forum | Fri Apr 07 16:12:37 EDT 2006 | craig_83
I would like to freeze feeders on a global basis. I am tired of table changeovers everytime I run a different board. A good example is today I ran 1 board which went well. I wanted to run a board behind it that had 99% the same parts. I am not necess
Electronics Forum | Wed Nov 04 07:39:34 EST 2009 | vetteboy86
We have started using an RGB LED and today ran the first boards down our line. I noticed an immediate issue with placing these. I'm using a quad QSP-2. The part sticks to the nozzle. The nozzles are clean. I have adjusted machine handling so that vac
Electronics Forum | Thu Nov 12 04:40:03 EST 1998 | Galen
| Scott - Good to see things are going well for you. With regard to your comments, Quad has introduced a complete line of Semi-conductor/APT machines (Q Series) that support both SMT and Semi-conductor applications. The machines were introduced in
Electronics Forum | Thu Mar 06 17:27:17 EST 2014 | bobpan
Does this happen with just 1 gantry? If so...I would think your encoder in that gantry/axis needs cleaned. I have seen digital i/o cards cause this issue. But usually you will notice this when opening and closing the doors. The head would sometimes
Electronics Forum | Tue Apr 23 12:17:28 EDT 2002 | binns
I have a couple of questions for you, and a couple of answers. 1. Which model ? (100, IIc, IVc, QSV, QSP ) 2. In reference to how the machine stacks up with Fuji and Panasonic. They have never stacked up. Those families of machines have historicall
Electronics Forum | Sat Aug 18 00:49:56 EDT 2012 | audere
When I see this on my QSP2 it is always caused by the nozzle not seating ideally but I tend to set my tolerances really tight. To test mount a nozzle and look at Z height. Now pick up the part (which in my case will suck the nozzle upward due to the