Full Site - : mydata tp-11 ufp (Page 5 of 20)

Mydata TP11-UFP won't initialize

Electronics Forum | Tue Jan 04 10:05:41 EST 2011 | ev

Checked that out but all fans are running. It seems to be a heat issue. I was able to get it going the next time I started a shift.

Mydata TP11-UFP won't initialize

Electronics Forum | Tue Jan 04 14:06:58 EST 2011 | cyber_wolf

First I would confirm that both of your X-motors and transducers are working through the service menu. After that start looking at the big power booster on the back of the machine.

Mydata TP11-UFP won't initialize

Electronics Forum | Tue Jan 04 15:11:57 EST 2011 | ev

The Xmotor tests just confirms that the hardware did not initialize.....unless I am looking at the wrong menu. I have external fans on the booster board and the X motor on the back of the machine as well as one blowing directly into the computer box

Mydata TP11-UFP won't initialize

Electronics Forum | Thu Jan 06 13:56:46 EST 2011 | ev

Thanks for this detail. The X wagon responds as per the instructions here so I'll give the cables a good inspection.

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Fri Oct 29 17:48:46 EDT 2021 | artem

Hello, I have found the problem. The capacitors on the PAIB board were leaking. They have even demaged some traces and vias on the PCB and the -5V supply on the PAIB board was not working anymore. Got it working again :)

Mydata TP11 UFP hardware initiation failure

Electronics Forum | Thu Jul 20 07:40:56 EDT 2006 | ev

I have a TP11 UFP without the hydra option and have had difficulty keeping it running. The latest problem is a hardware iniation problem which in the past was a PAIB board failure which I replaced about one year ago almost to the day. Has anyone seen

Mydata TP11-UFP won't initialize

Electronics Forum | Thu Dec 30 16:41:48 EST 2010 | dyoungquist

Hi Ev, We are running a TP9-2 which should be very similar to your TP11-UFP. I need a little more information to be able to help. Is it failing on the initialize hardware step? Or is it a different point in the start up sequence that it fails? Wha

MyData placement precision / alignment

Electronics Forum | Mon Aug 17 11:35:57 EDT 2020 | artem

Hello, I have some troubles with my MyData TP11-UFP with the precision of the placement. All the parts which are mechanically centered are slightly misaligned. Attached are some pictures of 0603 and a SOT23 part. I have made the calibration but it

Mydata TP11 UFP hardware initiation failure

Electronics Forum | Thu Jul 20 10:48:43 EDT 2006 | pms

Ev, This error could be caused by any number of problems. Is there an error message in the message window before hardware initiation error? If so, what is it? A failure in any axis (x,y,z,c,theta,y-wagon,tray-wagon) could cause your symptom. Paul

Mydata TP11-UFP won't initialize

Electronics Forum | Tue Jan 04 13:00:07 EST 2011 | bk

The only x fan i can think of would be the x belt motor fan which is on the back of the black box sticking out of the back of the machine. If it's a heat issue then first thing to do is replace the 2 filters behind the 2 vented covers located on the