Electronics Forum | Thu Apr 17 17:57:13 EDT 2014 | proy
Hello We use a 5 zone conceptronics HVN70 and never before have we had something we could not do including 6 layers Rohs complicated boards. Recently we had a larger - simple 2 layer board - all 1206's etc however there are 15 pcs of a LARGE high m
Electronics Forum | Sat Sep 26 02:09:39 EDT 2015 | aemery
Proc My field service back ground included Electrovert so I know reflow electrical quite well. I've worked on Heller, Conceptronic and Vitronics over the last few years and really there isn't a huge difference if you can read a schematic. I checked
Electronics Forum | Mon Sep 28 09:31:43 EDT 2015 | proceng1
Proc > > My field service back ground included > Electrovert so I know reflow electrical quite > well. I've worked on Heller, Conceptronic and > Vitronics over the last few years and really > there isn't a huge difference if you can read a > sc
Electronics Forum | Wed Jun 21 16:04:07 EDT 2006 | bman
"Another question, is the facility with 200A @ 208V able to operate this assembly line properly?" That could be a problem, big ovens pull a lot of juice. Our 7 zone Conceptronic HVN-102 runs on 480 Volts and is on a 160 amp breaker, for example. Y
Electronics Forum | Wed May 12 12:22:38 EDT 2004 | solderpro
I agree with the guy about cars, boats, ect... ok, I like as some have said without a doubt, DEK top of the line.... pick and place, love siemens but software is not user friendly, myself, JUKI all the way, great equipment, great software, that mean
Electronics Forum | Thu Feb 09 09:45:50 EST 2006 | PWH
I'm not familiar with the HVN70 programming but our conceptronic oven reacts well to adjusting the cooling fan speed at the end of the oven. However, TAL will likely be affected substantially by changing fan speed.
Electronics Forum | Thu Feb 09 09:36:55 EST 2006 | aj
All, I would like to find out if it is possible to adjust the cooling rate on a Conceptronic Reflow Oven Model HVN70. We do not use Nitrogen and the Cooloing system is Genesis GCM-1. From profiling it seems to be cooling too quickly. Any replies a
Electronics Forum | Thu Jul 21 06:14:28 EDT 2005 | aj
All, I have a Conceptronic HVN70 reflow oven with Genesis Cooling System. After profiling and checking the readings, the Cooling Rate seems to be very fast. Does anyone know if the cooling is adjustable? aj
Electronics Forum | Wed Jan 16 12:57:29 EST 2002 | Kevin Neal
Check all of the interlocks. The heaters and conveyor will not power up unless all of the interlocks are closed.