Electronics Forum | Tue Jun 14 15:02:13 EDT 2022 | glasscake
Start with fundamentals: Disconnect, clean and reconnect all inner connections, bulk heads, ext. Disconnect, reconnect all connections at the controller. Check wiring harness for conductivity. Clean everything appropriately, lube ways, balls screws
Electronics Forum | Tue Jun 14 16:23:22 EDT 2022 | glasscake
Cant put a finger on it being an encoder that was just a single possibility. You can always hook up a scope to the encoder and see if they are working appropriately. I would look through the machine's utilities and see if there is some debug or more
Electronics Forum | Thu Oct 15 10:21:30 EDT 2015 | azdback
troubleshooting a table lift error on MY12. Error code: F-MOT_Releaseboard conveyor lift/1304. Basically, the table got stuck on the up position. Also bench tested both lift motors and they are ok.Rotated the lift motors manually to test the encoder
Electronics Forum | Fri Jan 10 15:33:57 EST 2014 | hans88
Hello Rob, Thanks for your fast reply. I will check the parts you mentioned. You were right about the mot card we swaped it with a new one but that made no difference. Today we tried to find were the problem could be we: - removed the j1, j2 and
Electronics Forum | Fri Jan 10 03:33:42 EST 2014 | hans88
hello people, we have a my12 wich has a problem it gives the following error during hardware initialization: F-MOT-MSETDYN Y/1236 :Motor amplifier channel a error. after this error it says hardware initialization failed. this prevents us of using
Electronics Forum | Fri Jan 10 11:32:52 EST 2014 | rgduval
Hi, Hans, I would have suggested swapping the MOT card out to see if that fixes the issue (or, changing the MOT card with another one to isolate the card), but, it sounds like you've already done that. I'm surprised that MyData would point you towa
Electronics Forum | Mon Jul 16 10:45:47 EDT 2012 | cyber_wolf
The trandsducer on the motor.
Electronics Forum | Fri Oct 12 11:21:43 EDT 2018 | tech1
There are 2-X motors and numerous items that could be causing this: 1 of the X motors, 1 of the X transducers, 1 of the couplings connecting the motor and transducer, X Kevlar Belt. If you know how to go into the service portion of the software you
Electronics Forum | Wed Jun 27 18:10:34 EDT 2007 | kpm135
Just thought I'd let you know the problem was the Batteries. There happened to be three 6 volt 10 Ah batteries hooked in series that were no longer holding voltage. Also we ended up replacing the MI board because there was a fried component on it. Do
Electronics Forum | Tue Dec 18 21:47:14 EST 2012 | jaimebc
So just to update and close this thread, it was the ZFIB board ( the one mounted on top of the theta motor) that was causing the theta motor to error out) Problem fixed. $ 30 dls or so from MYDATA. Hope this helps some one down the road.