SMT Equipment

phoenix nanotom s - 180 kV/15 W Nanofocus Computed Tomography System

Company Information:

Development and production of microfocus and nanofocus X-ray-inspection systems for the electronic industries. Dedicated automation and user-friendly software. 24h servicing and maintenance available.

Camarillo, California, USA

  • Phone 805 389 0911
  • Fax 805 445 9833

See Supplier Website »

Company Postings:

phoenix nanotom s - 180 kV/15 W Nanofocus Computed Tomography System

phoenix nanotom s - 180 kV/15 W Nanofocus Computed Tomography System

Name:

phoenix nanotom s - 180 kV/15 W Nanofocus Computed Tomography System

Category:

Inspection

Offered by:

phoenix|x-ray Systems + Services Inc.

   

phoenix nanotom s - 180 kV/15 W Nanofocus Computed Tomography System Description:

GE's phoenix nanotom® s is the first 180 kV/15 W nanofocus computed tomography (nano ct) system perfectly tailored to applications e.g. in material science, precision injection moulding or micromechanics.

The nanotom® is the inspection solution for a wide range of 3D CT applications. Once scanned, the fully three dimensional CT information allows many possibilities for analysis. Precise 3D measurements of complex objects or the automatic generation of first article inspection reports within an hour are possible.

Key Features:

  • First 180 kV / 15 W nanoCT® system with low maintenance, longlife open X-ray tube
  • High precision rotation-unit with air bearing for accurate and reliable CT images
  • Granite-based manipulation and optional thermal stabilization for long-term stability and highest precison
  • Up to 2 times faster data acquisition at the same high image quality level by diamond|window (optionally)

Customer Benefits:

  • 4 operation modes from submicron to high-intensity applications
  • Automated generation of first article inspection reports in < 1 hour possible
  • Excellent software modules for highest CT quality and ease of use, e.g.
    • High precision and reproducible 3D metrology by click & measure|CT with datos|x: fully automated execution of CT scan,reconstruction and analysis process
    • Accelerated 3D CT reconstruction results within a few seconds or minutes (depending of the volume size) by velo|CT
  • Very compact system even for small labs

phoenix nanotom s - 180 kV/15 W Nanofocus Computed Tomography System was added in Mar 2008

phoenix nanotom s - 180 kV/15 W Nanofocus Computed Tomography System has been viewed 1743 times

SMT Feeders

Circuit Board, PCB Assembly & electronics manufacturing service provider