MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine
Company Information:
Name: |
MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine |
Category: |
|
Offered by: |
|
View MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine |
|
MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine Description:
MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine
X-Ray Solution MLX6600 Hardware technical parameters |
||||
H A R D W A R E |
X-RAY tube |
Tube type |
Sealed microfocus X-ray tube |
|
Tube voltage |
40-90kV |
|||
Tube current |
10-200uA |
|||
Focal spot size |
5-15μm |
|||
Cooling method |
Convection cooling |
|||
Detector |
Detector type |
HD digital flat panel detector (FPD) |
||
Imaging area |
130mm*130mm |
|||
Photosensitive unit size |
49.5μm |
|||
Pixel matrix |
1536*1536 pixels |
|||
Magnification |
1000X |
|||
Inclined Angle |
0-60° |
|||
Inspection speed and accuracy |
Repeated test accuracy |
3μm |
||
Software inspection speed |
3.0s/point (Excluding loading and unloading time) |
|||
Table |
Standard size |
440mm*540mm |
||
Load capacity |
≤5Kg |
|||
CNC programming |
Test parameters for different products can be stored in categories and called at any time. You can set the detection route or sequence of one or more products, and the program automatically completes the detection and stores the photos. |
|||
Operating platform |
Mouse, keyboard, 2 operating modes |
|||
Shell |
Inner lead plate |
5 mm thick lead plate (isolate radiation) |
||
Dimensions |
1360mm(L) * 1240mm(W) * 1700mm(H) |
|||
Weight |
About 1170Kg |
|||
Other parameters |
Computer |
24 inches Widescreen LCD/I3 CPU/2G Memory/200G hard disk |
||
Power supply |
AC 110-220V (± 10%) (International power supply) |
|||
Temperature and humidity |
22±3℃ 50%RH±10%RH |
|||
Total power |
1700W |
|||
Safety |
Radiation safety standard |
Adopt steel-lead-steel protection structure. Any position 20mm from the shell, radiation≤1μSV/H, in line with international standards |
||
Safety interlock function |
Two high-sensitivity limit switches are set in the door opening position for equipment maintenance. Once the door is opened, the X-ray tube will automatically power off immediately. |
|||
Electromagnetic switch protection |
The observation window has an electromagnetic switch, and the observation window cannot be opened when the X-ray tube is in working state. |
|||
Observation window |
With an observation window, the sample can be observed directly from the window while the machine is running. |
|||
Emergency stop |
The emergency stop is set in the prominent position of the operation console and the equipment body, can be pressed to quickly cut off the power supply system. |
|||
X-ray tube automatic protection |
Five minutes after the machine has no operation, the X-ray tube will automatically power off and enter the protection state. |
|||
Automatic machine protection |
Once any door or window of the machine is turned on, the machine immediately enters the shutdown protection state, and any operation cannot be performed. |
View MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine
MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine was added in Nov 2021
MLX6600 X-Ray Solution Microfocus X-Ray Inspection System Machine has been viewed 592 times
20 More Products from QYSMT SOLUTION USA LLC / Qinyi Electronics Co.,Ltd :