SMT Equipment

Honeywell 10201/2/1 Fail Safe Digitial Input Module

Company Information:

XIAMEN YUEHANG COMPUTER ENGINEERING CO.LTD.

XIAMEN YUEHANG COMPUTER ENGINEERING CO.LTD. is a company that professionally engaged in large system DCS spare parts supply. We supply DCS, PLC, MOTOROLA MVME, Anybus, RTU, IPC, IPC, SCSI (50, 68, 80Pin), AnyBus (Gateway)

Xiamen City, China

Manufacturer

  • Phone +8618020776786
  • Fax +86-0592-5165561
Company Postings:

(30) SMT parts, accessories & PCB supplies items

(11305) products in the catalog

Honeywell 10201/2/1  Fail Safe Digitial Input Module

Honeywell 10201/2/1  Fail Safe Digitial Input Module

Name:

Honeywell 10201/2/1 Fail Safe Digitial Input Module

Category:

Industrial Automation

Offered by:

XIAMEN YUEHANG COMPUTER ENGINEERING CO.LTD.

Honeywell 10201/2/1 Fail Safe Digitial Input Module Description:

Sales Manager: Sandy Lin

Email: unity@mvme.cn

Skype:onlywnn_1

Mobile(Whatsapp): (+86)-18020776786

yuehang: 

Shipping Term : TNT,DHL,FEDEX,ETC

Payment Term : T/T

Warranty: 12 month

yuehang supply: New+original+factory sealed+high quality

Service: quotation will be sent in 9 hours

Skype + whatsapp + mobile  =  24 hours /day   Oneline.

Application field
Company products are widely used in CNC machinery and metallurgy, oil and
gas,petrochemical, chemical, paper printing, textile printing and dyeing, machinery, electronic
manufacturing, automobile manufacturing, tobacco, plastic machinery, electric power,water
conservancy, water treatment / environmental protection, municipal engineering,boiler
heating, energy, power transmission and distribution.

Honeywell 10201/2/1  Fail Safe Digitial Input Module 

Honeywell 10201/2/1  Fail Safe Digitial Input Module 

Honeywell 10201/2/1  Fail Safe Digitial Input Module 

2.2.1.5 System flags / Diagnosis flags
M 00,00...M 254,15 : Binary flags
M 255,00 : Oscillator approx. 2 Hz
M 255,01 : Oscillator approx. 1 Hz
M 255,02 : Oscillator approx. 0.5 Hz
M 255,03 : Oscillator with period interval of approx. 1 minute
M 255,04 : Oscillator approx. 1/8 Hz
M 255,05 : Oscillator approx. 4 Hz
M 255,06 : Oscillator approx. 8 Hz
M 255,10 : Sum error message, signalizes that an error was detected by the PLC
M 255,11 : Error messageFK1, fatal error, detailed information in MW 254,00...MW 254,07
M 255,12 : Error messageFK2, serious error, detailed information in MW 254,08...MW 254,15
M 255,13 : Error messageFK3, light error, detailed information in MW 255,00...MW 255,07
M 255,14 : Error messageFK4, warning, detailed information in MW 255,08...MW 255,15
M 255,15 : Detection "new start"
MW 254,00...MW 255,15 : error messages
First cycle detection
M 255,15
This binary flag can be used for detection of the first program cycle after a program start. It is always set to "zero"
after each program start, independent of the initialization instructions given by the system constants. If this flag is
requested by the user program and then set to "1", it can be determined whether or not the user program was restarted.
2.2.1.6 CS31 status word
EW 07,15
Bit 0 = 1 : no CS31 error of class 2 present
Bit 1 = 1 : PLC has been adopted in CS31 cycle (only relevant when used as a slave)
Bit 2 = 1 : Time and date are valid
Bit 3 = 1 : Battery present
Bit 4...7 : unused
Bit 8..15 : currently determined maximum number of modules on CS31 system bus
(only relevant when used as a master)
2.2.2 Operands of 07 KR 31 and 07 KT 31
2.2.2.1 Available variables and constants
Inputs
E 00,00...E 61,15 : Digital inputs, CS31 remote module
E 62,00...E 62,11 : Digital inputs of the basic unit 07 KR 31 / 07 KT 31
E 63,14 : Digital inputs high-speed (Tv = 0.02 ms), signal identical to E 62,00
E 63,13 : high-speed counter, request "zero crossing"
EW 00,00...EW 05,15 : Analog inputs, CS31 remote module
EW 06,15 : high-speed counter, request "zero crossing"
EW 07,00...EW 07,07 : reserved (for diagnosis on the CS31 system bus)
EW 07,08...EW 07,14 : Read the real time clock
EW 07,15 : Status for CS31 system bus
Outputs
A 00,00...A 61,15 : Digital outputs, CS31 remote module
A 62,00...A 62,07 : Digital relay outputs of the basic unit 07 KR 31 / 07 KT 31
A 63,15 : high-speed counter, adopt inital value
AW 00,00...AW 05,15 : Analog outputs, CS31 remote module
AW 06,15 : high-speed counter, initial value

 Internal Operands
M 00,00...M 21,15 : Binary flags
M 230,00...M 239,15
M 255,00...M 255,15 : Diagnosis flags
S 00,00...S 15,15 : Steps
K 00...K 00,01 : Binary constants
MW 00,00...MW 05,15 : Word flags
MW 230,00...MW 239,15
MW 254,00...MW 255,15 : Diagnosis words
KW 00,00...KW 07,15 : Word constants
MD 00,00...MD 01,15 : Double word flags
KD 00,00...KD 01,15 : Double word constants
Time values for time functions
KD yy,xx : Time values for time functions such as ESV, ASV etc. are configured as double word constant or as
MD yy,xx : double word flags. Only integer multiples of 5 ms are permitted.
2.2.2.2 Direct constants
Direct constants are only permitted with function blocks on certain inputs. Where this is the case it is explained in
the description of the function modules.
# -32768...+32767
#H 0000...FFFF
2.2.2.3 Labels
Labels serve as jump targets for forward jumps and consecutive number blocks.
MA 0...999
2.2.2.4 System constants
Identical to chapter 2.2.1.4, except of:
KW 00,08 : not used
2.2.2.5 Diagnosis flags
Identical to chapter 2.2.1.5
2.2.2.6 CS31 status
Identical to chapter 2.2.1.6, except of:
Bit 2...7 : not used
2.2.3 Operands of 07 KP 62
2.2.3.1 Available variables and constants
Inputs
The module has no process inputs.
EW 00,04...EW 00,07 : high-speed inputs from ABB Procontic T200
Outputs
The module has no process outputs.
AW 00,04...AW 00,03 : high-speed outputs to ABB Procontic T200
Internal operands
MW 00,00...MW 05,15 : Output flags to ABB Procontic T200
MW 06,00...MW 11,15 : Input flags from ABB Procontic T200
MW 12,00...MW 253,15 : free word flags
Setting the cycle time
KD 00,00 : This constant serves as the specification of the cycle time for the PLC program. The cycle time
is given in milliseconds. Only integer multiples of 5 ms are permitted.

GENERAL ELECTRIC Q366A773G13 

CONVERTER CONCEPTS VT50-341-10/XX 

WOODMAN D-14689 PC 

RELIANCE 0-49022 

SIEMENS 6SE6410-2BB12-5AA0 MICROMASTER 410 

ABB DSQC-236T 

TELEMECANIQUE TSX-P57-103M 

HONEYWELL UDC2000 TEMPERATURE CONTROL DC2005-1-0000-FC30-00-W122

BENDIX 3730269 PC 

JOHN FLUKE 648782 POWER SUPPLY ASSEMBLY REV.E-1

RELIANCE ELECTRIC 0-52012-3 

POTTER & BRUMFIELD KR-5842 CN CR-90 

MANNESMANN REXROTH 4WE10E40/CW110N9DA 

JOHN FLUKE 793562 COMPUTER INTERFACE ASSEMBLY 2289A-3002

KUNKLE 6010HHM01-AM 2'' VALVE

VICKERS DG4S4-016C-B-60 

COMPUMOTOR 87-011790-01-A 

SIEMENS 7NG3242-0BB00 

ABB DSPC-157 MAIN COMPUTER BOARD 57310001-GP/2 

SIEMENS 7NG3242-0AA10 

PHOENIX CONTACT QUINT-PS / 1AC / 24DC / 20 POWER SUPPLY 2866776 

STAEFA CONTROLS SYSTEMS SMPI 598-50000-01 

LTN SH0850255004-025048BS ENCODER DC 16/13

REFURBISHED PARKER S6-DRIVE PARKER S6

FISHER PARTS/EMERSON 37B2889X012 

OHIO GEAR RA2 GEAR REDUCER 1:1 RATIO

COLT INDUSTRIES M1756-U50670 PC 

ALLEN BRADLEY 800H-FPXP16WD4 

ALLEN BRADLEY 142530 

FANUC A16B-1210-0290/01A PC 

GENERAL ELECTRIC JCD-0 CURRENT TRANSFORMER 750X31G9 

PULSATRON LB02SA-PTC1-G19 

ALLEN BRADLEY 151123 PC 

ALLEN BRADLEY 160-AA08NSF1 

HYDAC 00907302 HDA 4744-A-100-000 907302

ATLAS COPCO 1619-5332-01 

HONEYWELL RM7890A1007 

WESTINGHOUSE PCE-111-003 I/O 

ALLEN BRADLEY 1771-OFE1 / B OUTPUT 

PUMP ASSEMBLY GP3S47ZEPE94TS

JOHN CRANE C18909 SEAL ASSEMBLY CARTRIDGE TYPE, 1102 SIZE, 2.125IN

FLOWSERVE WAY 876115 

ARISTA 6824A 

HUB CITY 0220-03516-066 

HONEYWELL MEASUREX 101138-01 PC BOARD REV.B 

P & H HARNISCHFEGER 79U16D4(L) 

FLOWSERVE ACE7A2Z ACTUATOR 700LBS 

CARLSON 5852C CLUTCH / BRAKE POWERFLOW B-27611

Honeywell 10201/2/1 Fail Safe Digitial Input Module was added in Jan 2018

Honeywell 10201/2/1 Fail Safe Digitial Input Module has been viewed 154 times

20 More Products from XIAMEN YUEHANG COMPUTER ENGINEERING CO.LTD. :

Jade Series Selective Soldering Machines

Jetting Pump for Integration