• SMTnet
  • »
  • Technical Library
  • »
  • Cleaning Flux Residue under Leadless Components using Objective Evidence to Determine Cleaning Performance

Cleaning Flux Residue under Leadless Components using Objective Evidence to Determine Cleaning Performance

Published:

August 14, 2019

Author:

Mike Bixenman - KYZEN Corporation, Vladimir Sitko, Pavel Hub - PBT Works

Abstract:

Cleanliness is a product of design, including component density, standoff height and the cleaning equipment’s ability to deliver the cleaning agent to the source of residue. The presence of manufacturing process soil, such as flux residue, incompletely activated flux, incompletely cured solder masks, debris from handling and processing fixtures, and incomplete removal of cleaning fluids can hinder the functional lifetime of the product. Contaminates trapped under a component are more problematic to failure. Advanced test methods are needed to obtain "objective evidence" for removing flux residues under leadless components.

Cleaning process performance is a function of cleaning capacity and defined cleanliness. Cleaning performance can be influenced by the PCB design, cleaning material, cleaning machine, reflow conditions and a wide range of process parameters.

This research project is designed to study visual flux residues trapped under the bottom termination of leadless components. This paper will research a non-destructive visual method that can be used to study the cleanability of solder pastes, cleaning material effectiveness for the soil, cleaning machine effectiveness and process parameters needed to render a clean part....

  • Download Cleaning Flux Residue under Leadless Components using Objective Evidence to Determine Cleaning Performance article
  • To read this article you need to have Adobe PDF installed

You must be a registered user to talk back to us.

 
Company Information:

KYZEN Corporation

A leading supplier of precision cleaning chemistries to the worldwide electronics, metal finishing, medical, semiconductor, and optical industries.

Nashville, Tennessee, USA

Cleaning

  • Phone 615-831-0888
  • Fax 615-831-0889

KYZEN Corporation website

Company Postings:

(32) products in the catalog

(8) technical library articles

(511) news releases

  • Jun 15, 2021 - Dispensing EMI Shielding Materials: An Alternative to Sputtering | Nordson ASYMTEK
  • Feb 20, 2021 - Humitector™ Type 2 Non-Reversible Humidity Indicator Cards from Clariant help assure the integrity of moisture-sensitive surface-mount devices | Clariant Cargo & Device Protection
  • Jan 03, 2021 - Reflow Soldering Processes and Troubleshooting: SMT, BGA, CSP and Flip Chip Technologies | SMTnet
  • Dec 07, 2020 - A Non-destructive Approach to Identify Intermittent Failure Locations on Printed Circuit Cards (PCC) that have been Temperature Cycle Tested | ACI Technologies, Inc.
  • Dec 02, 2020 - SMT007-MIRTEC Intelligent Factory Automation Article-November 2020 | MIRTEC Corp
  • Browse Technical Library »

Cleaning Flux Residue under Leadless Components using Objective Evidence to Determine Cleaning Performance article has been viewed 722 times

  • SMTnet
  • »
  • Technical Library
  • »
  • Cleaning Flux Residue under Leadless Components using Objective Evidence to Determine Cleaning Performance
SMT spare parts - Qinyi Electronics

ICT Total SMT line Provider