Noise Fault Detection of High Low Temperature Test Chamber(Climatic chamber)

Published:

April 11, 2019

Author:

Climatest Symor

Abstract:

With the development of science and technology, the climatic chamber quality has been improved, and the failure rate is reduced, but there still have the failure probability.today we introduce what are the mian factors for big noise high low temperature test chamber: 1.External factors: the bottom angle is uneven, the ground is uneven, adjust the bottom angle, ensure the equipment is in a horizontal position; 2.The equipment is touched other objects or pushed against the wall,pls remove the objects and keep a certain distance from the wall. 3.Compressor noise:check whether the compressor collides with the pipeline,and evaporator dish is loose or not. 4.Check whether compressor shock absorbers are aging and replace them. 5.Solenoid valve noise: solenoid valve reversing caue loud sound, pls add damping glue, if no effect, need to replace solenoid valve. If there is AC noise, need to replace the power board. 6.Check wether the fan or the fan string shaft make noise,whether the fan blades are touched and deformed, whether the fan is fixed or not, pls adjust accordingly or add the rubber pad. If further technical questions,contact us without hesitation!---Climtest Symor® technical team...

  • Download Noise Fault Detection of High Low Temperature Test Chamber(Climatic chamber) article

You must be a registered user to talk back to us.

 
Company Information:

Symor Instrument Co.,Ltd

Manufacturer of electronic dry cabinets,our dry cabinets includes J-STD-033 and RoHS compliant dry cabinets,such as 1%-5%RH,1%-10%RH,10%-20%RH,20%-60%RH,1%-60%RH Nitrogen cabinets.our company is ISO 9001:2015 certified.

Hefei, China

Antistatic

  • Phone +8655163853683

Symor Instrument Co.,Ltd website

Company Postings:

(8) products in the catalog

(6) technical library articles

(5) news releases

(1) job posting

  • Jan 02, 2019 - Risk Mitigation in Hand Soldering | Metcal
  • Apr 27, 2018 - Understanding the Heat Output of your BGA Rework Station | Precision PCB Services, Inc
  • Apr 27, 2018 - Hot Air vs. IR BGA Rework Stations | Precision PCB Services, Inc
  • Feb 22, 2018 - Hand Soldering with Lead Free Alloys | Metcal
  • Dec 07, 2017 - Utility of Dual Applicators for Non-Atomized Conformal Coating to Improve High-Volume Manufacturing Optimization | Nordson ASYMTEK
  • Browse Technical Library »

Noise Fault Detection of High Low Temperature Test Chamber(Climatic chamber) article has been viewed 47 times

Led tester

Electronics Auditor Job