3. Precautions and Conditions
Operation precautions
1. The focus of the CCD lens cannot be adjusted at will.
2. The working voltage is generally between 60KV and 90KV, the current is used in the
range of 0.08mA, and the voltage generally does not exceed 90KV.
3. To avoid the X-ray tube from being impacted by other objects, so the light tube part cannot
be touched.
4. When lead glass is damaged, it cannot be replaced with ordinary glass, please contact the
manufacturer.
5. There is 90KV high voltage inside the machine, and the grounding wire must be firmly
connected.
6. When stopping detection, please put the machine in OFF state.
7. Please notify the manufacturer in time when the current and voltage cannot be adjusted.
8. The total rate of the machine is 1500W, single-phase 220V and Current 10A.
Grounding Wire Conditions:
There is a 90KV high voltage inside the X-Ray machine, and all the high voltage loop
current flows into the earth, so there must be a good independent grounding wire. After the
machine is newly installed or moved, it must be connected to the ground wire before it can
be used.
When connected with the earth, the resistance is not more than 4 ohms.
The ground connection must be greater than or equal to 2.5mm.
The ground connection must be led out from the grounding copper bar of the power
distribution line, and there must be no branch connection in the middle.
The ground wire must be yellow and green double colors.