Electronics Forum | Sat Aug 07 02:28:20 EDT 2010 | raghu
We have PVA 350 benchtop dispensing equipement with humiseal 1A33 CC material. is there any moisture measurement process in conformal coating material?
Electronics Forum | Fri Feb 18 15:27:38 EST 2005 | jluckenbaugh
Frank R, I believe the Dymax #984-LVUF is a POLYURETHANE RESIN. I have used Humiseal 1A27 and 1A33 for several years with great success. Both of these materials are High VOC materials. If your customer does not require these materials to be aproved
Electronics Forum | Mon Aug 20 09:49:57 EDT 2018 | dontfeedphils
Not entirely clear on your question. We don't coat any of our hardware (assemblies are coated prior to hardware installation), so if coating needs to be reworked after this, then hardware removal is needed.
Electronics Forum | Sat Aug 18 10:35:41 EDT 2018 | mgerrior
Hey Phil, i'm just curious what your rework processes are for your hardware after conformal coating is applied (if any). I'm interested in conformal coating as our hardware can be exposed to moisture rich environments at customer sites but to my kno
Electronics Forum | Tue Jul 03 01:54:42 EDT 2018 | rdhiman1
Reaching out to all conformal coating experts, please help! While setting up conformal coating using the automated atomized spray, we observing issues associated with conformal coating wetting on the following regions: 1) Component edges 2) Metalli
Electronics Forum | Tue Aug 14 16:18:48 EDT 2018 | dontfeedphils
A couple of things to try as I just went through this myself. Checkout this link for pointers on plasma cleaning... http://www.nordson.com/~/media/Files/Nordson/march/Papers/The-Effects-of-Plasma-Treatment-Prior-to-Conformal-Coating-NordsonMARCH.p
Electronics Forum | Mon Jan 28 11:50:23 EST 2013 | johng
Good morning Mark, No issues around the masking at this point. The issue seem to be in open areas as well as between clad runs. We are using Humiseal 1A33 Conformal Coat.