Full Site - : 30% humidity (Page 16 of 29)

Low humidity control

Electronics Forum | Wed Feb 02 06:58:07 EST 2011 | mikeyjryan

Hello, The company I work for are located in the North of Spain and the humidity levels in the factory range from 10 to 60 %RH. We have concerns about the low humidity effects on our ESD controls and want to invest in a system to keep the humidity a

Re: humidity in PC packages

Electronics Forum | Mon Jun 21 16:11:41 EDT 1999 | John Thorup

| | I am finding that some of our IC's are coming from the supplier with the humidity gauge in the bag reading 10-20%. Has anybody done any tests to determine what humidty level in a package will cause problems during reflow? | Usually a proper m

MSD Control in low humidity environment

Electronics Forum | Wed Aug 05 18:36:19 EDT 2015 | caurbach

John, I assume you mean 60%, not 65%. J-STD-033 has a derating table for floor life which accounts for conditions other than 30C/60% RH. Table 7-1 is what you're looking for I believe. Adam

MSD Control in low humidity environment

Electronics Forum | Tue Aug 04 23:50:20 EDT 2015 | johnwnz

Hi folks, I was wondering what the combined wisdom was on the humidity effect on the MSD control required by the Jedec std. The std works on a relative humidity of 65%, if my RH is only say 30% because of factory environments how do I easily factor

How does temperature and humidity effect solder paste/printing

Electronics Forum | Wed Apr 11 22:05:58 EDT 2001 | davef

OA pastes are more hydroscopic than NC pastes. Hydroscopic. The capacity of a material to absorb and retain moisture from the ambient air. Sometimes this is compounded if you remove paste from the frig and let it warm to room temperature, because

Need help on assessment of effect of temperature and humidity in battery consumption

Electronics Forum | Tue Apr 24 21:00:58 EDT 2018 | marlonbc

Hi All, Would just like to course through this concern on a product that we are contracted to assemble. It is mainly used for an automatic hand sanitizer dispensing product. By design there is a restrictive value of current that it needs to dissipat

SMT room environment

Electronics Forum | Tue Jan 10 11:38:27 EST 2017 | charliedci

68 to 72F, 25 to 30% humidity. IPC might have exact numbers.

J-STD-001 Par 4.2.2 Temperature and Humidity

Electronics Forum | Mon Jul 16 15:44:27 EDT 2007 | davef

J-STD-001 doesn't necessarily require additional controls under conditions of low humidity, only that you verify the effectiveness of what you have in place. ESD S20.20 [1999] only says that relative humidity above 30% is "desirable". ESD S20.20 [200

Re: Controlled TempHumidity rooms

Electronics Forum | Wed Dec 09 15:54:05 EST 1998 | Dave F

| Hi, I know for sure that by controlling temp. and humidity | conditions in SMT assy lines room, one gets advantage in | screen printing, adhesive dispensing, and pick&place | machines mainteinance. Does any one have any advice on why | else is a c

what is the ideal RH level at warehouses?

Electronics Forum | Mon May 30 09:11:15 EDT 2011 | davef

3a ANSI/J-STD-001: * Temperature and Humidity: 18-30°C, 30-70%RH ** If out of range, shall verify electrostatic discharge control program according to ANSI/ESD S20-20 is adequate. ** For process control, more restrictive temperature and humidity lim


30% humidity searches for Companies, Equipment, Machines, Suppliers & Information

Best SMT Reflow Oven

High Throughput Reflow Oven
pressure curing ovens

Training online, at your facility, or at one of our worldwide training centers"
pressure curing ovens

World's Best Reflow Oven Customizable for Unique Applications
Online Equipment Auction of Altronic: Small-Batch Surface Mount & Assembly Facility

Wave Soldering 101 Training Course
PCB separator

Training online, at your facility, or at one of our worldwide training centers"