GEM Expo is Brazil's only trade show to focus only on equipment and materials for the manufacture and assembly of electronics
Industry Directory | Manufacturer
CPC Technologies Ltd. We are specializing in the Printed Electronics field, as well as in the Touch Panel/membrane switch manufacturing.
Electronics Forum | Mon May 31 19:20:50 EDT 1999 | Raeto Zryd
I have difficulty to convince my management to air-condition our manufacturing facilities. The room temperature fluxuates from 8 deg.C in the morning to 25 deg. C in the afternoon. The PCB topside temperatures in the reflow oven and wave soldering ma
Electronics Forum | Fri Feb 22 01:58:21 EST 2002 | Marcus
Armin, another argument ist that the range of available options /features is totally different. E.g. automatic stencil wipers, aircondition or post print inspection systems are only avilable in auto�s. These options are also important to stabilize y
Used SMT Equipment | Soldering - Reflow
Features 1. Full hot air reflow heat fast, high thermal efficiency compensation, delta t less than ± 2 ℃ soldering is uniform. 2. HELLER company has 40 years of history, process maturity. 3. maintenance costs low, the furnace normal use, electrici
Industry News | 2010-02-08 12:17:16.0
Naples, FL, February 3, 2010 — Trafalgar Publications Ltd., a global media provider of high-technology exhibitions, conferences and publications, announces Global Electronics Manufacturing Expo Brazil 2010. The event will be held at the prestigious, state-of-the-art Expo Center Norte in São Paulo, Brazil on October 5-7, 2010.
Industry News | 2023-06-07 19:53:22.0
On May 17, 2023, IPC and Taiwan Electrical and Electronic Manufacturers' Association (TEEMA) signed a Memorandum of Understanding (MoU) at the Electrical Wire Processing Technology Expo (EWPTE) in Milwaukee, Wis., USA. The MoU aims to promote the adoption and use of IPC-2591, Connected Factory Exchange, the plug-and-play industry standard for factory communication which sets the baseline for companies to achieve Industry 4.0.
Technical Library | 2016-11-10 17:37:35.0
The demand for compute capability is growing rapidly fueling the ever rising consumption of power by data centers the worldwide. This growth in power consumption presents a challenge to data center total cost of ownership. Free-air cooling is one of the industrial trends in reducing power consumption, the power usage effectiveness (PUE) ratio, and the total cost of ownership (TCO). Free-air cooling is a viable approach in many parts of the world where the air is reasonably clean. In Eastern China, the poor quality of air, high in particle and gaseous contamination, is a major obstacle to free-air cooling. Servers exposed to outside air blowing in to data centers will corrode and fail at high rate. The poor reliability of hardware increase TCO dramatically. This paper describes a corrosion resistant server design suitable for reliable operation in a free-air cooling data center located in Eastern China where the indoor air quality can be as poor as ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) severity level G3. An accelerated corrosion test method of verifying hardware reliability in the ASHRAE severity level G3 environment is also described.
Career Center | , | Engineering,Production
Project Management, SMT Process Engineering