Electronics Forum | Wed Oct 18 19:52:09 EDT 2006 | davef
Ted Dangelmayer's book [ESD Program Management: A Realistic Approach to Continuous Measurable Improvement in Static Control; Dangelmayer, T; Kluwer Academic Pub 1999 e2; 0412136716] is excellent. Often, ESD supplies sales-types use the "Chicken Littl
Electronics Forum | Wed Sep 20 16:15:53 EDT 2017 | davef
Some requirements to consider are: * Humidity and temperature controlled according to J-STD-001 * Electro-static discharge (ESD) control program according to ANSI/ESD-S-20.20. * Soldering technicians are trained and certified according to J-STD-0
Electronics Forum | Mon Jun 17 21:16:19 EDT 2002 | davef
You�re correct about J-001. It�s interesting though, I find no references to controlling temperature and humidity as an element of an electrostatic discharge control program in the following: * ANSI/ESD S20-20 * "ESD Program Management" by Ted Dan
Electronics Forum | Thu Sep 29 10:21:11 EDT 2011 | davef
1. Floor loading requirement - The designer of your factory building specified the flooring with a certain floor loading capability. You need to determine that capability. You plan to install machines and equipment. You need to determine the weight o
Electronics Forum | Sat Jul 22 03:27:36 EDT 2023 | shrikant_borkar
hi here are consolidated inputs to you you must validate before establishing your process. ESD-safe Material: Ensure that the masking tape is made of ESD-safe materials that have low triboelectric charge generation. Common materials used in ESD-sa
Electronics Forum | Wed May 03 20:04:21 EDT 2000 | Dave F
Joe: Hey, just hose everyone down with water when your humidity starts to decrease to below 40%. ;-) Actually, that�s how some humidity controllers work, when added to your heating system. Well basically that�s how they work. I�m not tryin� to
Electronics Forum | Mon Feb 10 21:19:51 EST 2003 | MA/NY DDave
Hi I am in favor of the best money can buy tiles, and everything including an ESD officier and training for everyone. Long term less money is spent and ESD protection is kept high continually. Boy do I have stories like the cleaning guys who put on