Electronics Forum | Thu Aug 14 03:54:59 EDT 2014 | ermani9
Failing to origin the machine. On pressing ORIGIN, it moves a small distance and gives the message "ORIGIN INCOMPLETE" and displays error ...243:Y DRIFT ADJUSTMENT NO GOOD..." Please help.
Electronics Forum | Thu Aug 13 05:28:45 EDT 2015 | dilogic
We had occasional problems and usually solve it by pulling out pogo pins slightly to extend them a bit... Also note that electric feeders have "reel empty" sensor that gives the same error message (if you are using cut tape strips without reel)
Electronics Forum | Mon Dec 14 06:26:16 EST 2015 | fredmoulin
Hi guys, I got a problem with our DEK 265 GSX : This message appears : 1300044 - Failed to perform Lighting calibration. Please, what does it mean, and how can I solve it ? Thanks very much.
Electronics Forum | Wed Apr 27 20:32:22 EDT 2016 | sonavc
Hi, I have DEK 265GSX. Just got error message " BOARD STOP NOT RETRACTED" Any help would be greatly appreciated. Thanks
Electronics Forum | Fri Jul 21 08:42:16 EDT 2017 | davef
Try: Mycronic Inc, 320 Newburyport Turnpike, Rowley MA 01969-2002; T: +1 978 948 6919 F: +1 978 948 6915
Electronics Forum | Fri Dec 15 11:01:14 EST 2017 | robertorocco
I have one Topaz X FNC machine with this problem. The head 2 FNC not change the nozzle. The head 4-6-8 is ok and change, but head 2 no, when he tries to change the nozzle he gives me an error message. What could be the problem?
Electronics Forum | Tue Feb 06 11:48:55 EST 2018 | romford_navy
Hi Does anyone know how to change error messages coming up in Korean rather than English This has occurred after new software installation on Samsung CP40CV
Electronics Forum | Mon Jul 30 17:31:59 EDT 2018 | dekhead
That error message is keyed by a hardware (soldered) link on the backplane board of the Y1 (motor controls), through direct cable to PCIB40#3... check connections both ehds; possibility of multiple PCIB failures?
Electronics Forum | Thu Mar 21 02:52:59 EDT 2019 | bukas
looks like home sensor problem, whats the error message? does head 6 now work properly?
Electronics Forum | Fri Jul 19 11:16:21 EDT 2019 | dman97
And yes if the proper data is not correct it will give you a error message because Flexa cannot communicate with the CP6.