Electronics Forum | Tue Aug 17 11:51:52 EDT 2010 | arek
Hi, I bought Philips CSM machines (CSM66-III and CSM84V-III). I need flopy disc with some files (MCH, VIS, FDR). I created MCH file but the machine send me an error message: BAD FORMAT DATA. Could anyone help me and send me correct files. Thanks
Electronics Forum | Tue Oct 05 16:53:31 EDT 2010 | loyrickie
Never seen, or worked on one of these machines. After turning the unit on and hitting f5 to return to origination, I receive error message "37- Head LOWER POS. SENSOR OFF!". I also have no service manual, just replacement parts catalog and operatio
Electronics Forum | Wed Feb 23 22:56:46 EST 2011 | jeffr
When I enter the "Setup Table Contact" menu, then press "Load PCB" the squeegee head should move to a mid position that I can set the squeegee height, but instead it moves the squeegee head to the front limit and displays a red error message about th
Electronics Forum | Thu Dec 22 18:54:30 EST 2011 | dwoodbury
Hi. We are having constant error messages from a Fuji QP341/MTU9 tray unit. It says there is a safety relay failed to start in prescribed time. Nothing we do seems to fix it, but rebooting enough times and eventually it goes away. We changed relay bo
Electronics Forum | Wed Aug 08 14:32:50 EDT 2012 | leemeyer
According to Quad data sheet, the max process temp on a ZCR oven is 310C. I am taking a guess that the "Critical Temperature" message may be Quad's way of saying that you have entered to high of a setting. Try bringing the setpoints to something belo
Electronics Forum | Wed Oct 03 22:25:01 EDT 2012 | haiae
After many trying to find equivalent Renco encoder for my Contact 3AVX, I get it. My machine is running well without any errors after installing a new Rencode encoder. I hope, this message can help some one who has the same problem as my problem. Ple
Electronics Forum | Wed Nov 06 12:58:56 EST 2013 | bobpan
The key to figuring out mirae machine failures 'most of the time' is found in mr-terminal. Is this message from mr-terminal or is this the windows/program software error. Mirae 1010 machines have boot failure problems often. Sometimes if the z positi
Electronics Forum | Mon Jan 20 13:06:05 EST 2014 | danooon
Have a problem with TRM-03. Today, after "RAM-error" message, my TRM-3 became a TRM-1 (on display). Menu is almost empty, but the biggest problem, that the middle segment is not working together with first and third. PCB is just stopping before the m
Electronics Forum | Fri Jul 10 18:47:27 EDT 2015 | alphatronique
make sure noting stock in the X ,and motor brake work usually machine supply 24V to motor brake wire for release brake then move until hit the end stopper for init motor if brake keep on that will the error message i got it often on the Z cause
Electronics Forum | Sat Sep 05 16:09:10 EDT 2015 | emanuel
Need assistance - I want to disconnect an unused LCS module from an Emerald machine. I disabled the tray changer and buffer conveyor in the machine's configuration but I still get an L212 error on the bottom of the screen and the machine hangs during