Electronics Forum | Sun Apr 23 09:04:36 EDT 2006 | kanna
Does anyone have any experience with these ovens > ? We are looking at purchasing a used > one. Anything in particular I should look at > when inspecting it ? > > Any comments good or bad > appreciated..... > > Thnx, Sr. i have one problem he
Electronics Forum | Thu Sep 15 13:52:40 EDT 2005 | pr
We had 2 at my last company. As I recall we had a hell of a time with bad blower motors. I'm not sure how you'd check on that, but maybe that problem has been fixed by now (it's been a few years). good luck, pr
Electronics Forum | Thu Apr 27 04:52:06 EDT 2006 | slaine
Ive a 5 zone vip 90, running at temperatures up to 280 degrees, biggest problem we have is with the fan moters siezing up. think we must have changed 8 out of 10 of them ok there 10 years old but it can be a lot of hastle. they sieze absolutly solid.
Electronics Forum | Mon Apr 24 14:04:44 EDT 2006 | pjc
You did not tell us where your boards fit on the thermal mass range. That is key. I've run Pb Free low to medium thermal mass boards with good results on a 5 zone oven (5 top/5 bottom). You should not have a problem running a medium thermal mass boa
Electronics Forum | Thu Jun 09 07:23:03 EDT 2005 | ajaydoshi
We have BTU150 paragon. Frequent failure obseve in cooling fan capacitor. Cooling zone temperature reach up to 80 degree centigrade How to prevent same. ajay
Electronics Forum | Tue Jun 28 00:11:44 EDT 2005 | ajaydoshi
We do have BTU 150 Paragon oven. Link fail problem occume most of the time during start of day or after Sunday. It never haven while running continiously, Any Suggestion. Ajay
Electronics Forum | Sat Dec 10 22:31:16 EST 2016 | ecogroup
Hi Tom, We have a Paragon 150 with the FCU board problem. We are thinking about finding another board and swapping it . Did you get the ROM chips from BTU when you swapped the FCU board? Appreciate any advice. Thank you. Ray
Electronics Forum | Tue Jun 04 11:17:39 EDT 2019 | dman97
Does anyone have a manual for a BTU PYRAMAX 150N X5 oven? We recently got one of these used and it has the flux management system attached along with a water chiller. We hooked everything up, but the oven throws a water supply problem alarm. Chill
Electronics Forum | Tue Dec 03 10:21:11 EST 2002 | jimlew
I don't think I can post pics in this (if anyone knows otherwise let me know), so I will email them to anyone who's curious. Here's the answers to your questions: Placement Force: 0201s are placed on the Siemens S23s with 1 newton of force. The s
Electronics Forum | Tue Dec 03 20:54:57 EST 2002 | davef
Q1:A picture of the sectioned MLCC would be nice. A1: I don't think I can post pics in this (if anyone knows otherwise let me know), so I will email them to anyone who's curious. R1: You�re correct. You cannot post pix on SMTnet. Please email me t