Electronics Forum | Sat Dec 10 22:31:16 EST 2016 | ecogroup
Hi Tom, We have a Paragon 150 with the FCU board problem. We are thinking about finding another board and swapping it . Did you get the ROM chips from BTU when you swapped the FCU board? Appreciate any advice. Thank you. Ray
Electronics Forum | Mon Nov 01 09:56:57 EDT 2021 | richardcargill
Update - Solved On talking with BTU they mentioned that if the conveyor is always running full speed then cleaning out the motor brush area with compressed air will cure it. I'm guessing that the carbon dust had encroached onto the encoder. A good b
Electronics Forum | Fri Feb 25 16:16:01 EST 2005 | pjc
Here are some 5 zones models to look for: Electrovert OmniFlo5 Conceptronic HVA70 BTU VIP70 Vitronics SMR or XPM 520 Heller 1088 (4 zone)
Electronics Forum | Thu May 26 21:07:22 EDT 2005 | KEN
This is caused by cte mis-match. The balls in the corners are short and fat. The balls near the null point are tall and more normalized. I don't remember what the zone settings were... BTU VIP98 BS was probably 22-25 IPM
Electronics Forum | Tue Jun 07 05:15:45 EDT 2005 | blueflag
Help Please could anyone advise when we run shutdown after 45 mins it should shut off . But we are still left with conveyor running also fans . regards Colin
Electronics Forum | Tue Jun 07 22:01:56 EDT 2005 | KEN
run shutdown.rcp after 45 minutes computer will load shutoff.rcp. Is this file not being loaded? If yes, then you have not defined the shutoff event in the scheduler. Poke around in the scheduler. Or check out the software manual. someone probab
Electronics Forum | Wed Oct 19 11:43:16 EDT 2005 | dougs
Ken is right about the BTU VIP's, we have 2 both about 6 years old as well, i've been here 1 1/2 years and only replaced a 15V power supply on one of them, no other issues at all.
Electronics Forum | Wed May 24 08:50:33 EDT 2006 | stepheniii
how many zones? And what settings are you using now? And you won't get it exactly like the data sheet, especially the cool down.
Electronics Forum | Wed May 24 10:40:22 EDT 2006 | dougs
Do you really need to have that shape of profile, why not have a gradual ramp then spike? Which paste are you using?
Electronics Forum | Wed May 24 21:58:12 EDT 2006 | KEN
I have 4 of these furnaces. Give me your length, width, mass (grams) and I'll run this through our system and get you close.