Full Site - : btu vip 98a (Page 9 of 20)

BTU VIP70 3 Phase supply

Electronics Forum | Wed Jun 21 16:30:07 EDT 2006 | GS

Hi Dallen, I do not know BTU VIP70 oven, any way make sure if it is not yet wired for 480 V 3Ph (wiring diagram), may be it needs just to reset wiring on terminal block in order to run at 480V. Best if you ask BTU. If not, you have to buy a Transfo

BTU VIP70 3 Phase supply

Electronics Forum | Tue Jun 20 08:40:40 EDT 2006 | dallen

This is a long shot, but can anybody advise on the supplies for a BTU oven. It is currently in the UK and is supplied by a 415V 4 wire. That is 3 phases and a neutral. We need to ship it to our plant in Mexico where they have a 480V 3 wire supply.

BTU VIP98 Leadfree Recipe

Electronics Forum | Wed May 24 13:10:28 EDT 2006 | Chunks

VIP 98, I believe that's a 7 zone if I can remember 6 years ago. Try 150, 165, 200, 235, 235 and 235 (top and bottom temps) with a belt speed of 35 inches per minute. This should get you in the ball park depending on the size of your board.

Repair a BTU VIP70 or buy a new HELLER??

Electronics Forum | Thu Nov 09 15:00:59 EST 2006 | jwentz

Shipping might be an issue for you but I have a VIP70A in storage that is roughly the same vintage but in really good shape for $5000. We pulled it from service last year to bring in a more Pb-Free capable oven. We are still running a sister oven on

BTU VIP98 Calibration

Electronics Forum | Mon Aug 27 12:33:46 EDT 2007 | emilio1

Hello everyone; I was wondering if anyone has/knows where to get, VIP98 FCU calibration procedure. I know its a long shot but need to calibrate a few ovens and we�d like to see if its possible to do this in house, as we have a calibration lab.

BTU VIP 98 Problem

Electronics Forum | Mon Oct 01 19:44:49 EDT 2007 | marcelll

Just bought a used VIP 98 and I have an alarm. Computer don't communicate with the embedded controler of the oven. I've check the cabling, OK, and there's power on the controler. The PC is booting normally. The controler is plug in the serial port 2

BTU VIP98

Electronics Forum | Wed Sep 15 17:14:05 EDT 2010 | jwentz

Seems we had similar issue years ago with our VIP 70. There are a series of 2pin axial fuses on the panel with the SS relays and contactors (I don't think it was over the FCU). Check each fuse with a meter; replaced ours and the e-stop cleared and th

Repair a BTU VIP70 or buy a new HELLER??

Electronics Forum | Sat Nov 04 11:57:20 EST 2006 | joseluis_amper

Hello, I have an oven with a big fail. The Control Unit. It is a 5 zones oven (BTU VIP70)and has more than 10 years, and I think that now is not interesting to repair. I think to buy an offer, an oven Heller of 7 zones + cool,(better for lead free).

BTU VIP speed configuration

Electronics Forum | Mon Oct 25 13:06:54 EDT 2021 | richardcargill

Can anyone shed any light on the Speed configuration setting on a BTU VIP70? We're using Winconv2.4a if that matters. There are only 3 editable fields in the configurator, Pulses per unit - Power - Distance. I'm struggling to find out what constitu

BTU VIP70 3 Phase supply

Electronics Forum | Mon Jun 26 04:41:06 EDT 2006 | dallen

Thanks for all the responses. BTU has now informed that the reason it is so expensive is the oven heaters need completely rewiring and some work in the transformer area etc is required. Also, we have to pay for engineering work for them to know wha


btu vip 98a searches for Companies, Equipment, Machines, Suppliers & Information