Electronics Forum | Thu Jun 22 03:24:20 EDT 2006 | slaine
Hi Im in the UK and have a BTU VIP70. BTU UK are normally quite helpfull, and will probably explain whats involved if you phone them ask for a guy called Tim Hogarth. My guess is it will need a new transformer and rectifier but im more electronics th
Electronics Forum | Sat Nov 06 06:38:24 EDT 2021 | ttheis
Thanks for posting the solution; this may come in handy some day for our vip70.
Electronics Forum | Thu Nov 09 15:00:59 EST 2006 | jwentz
Shipping might be an issue for you but I have a VIP70A in storage that is roughly the same vintage but in really good shape for $5000. We pulled it from service last year to bring in a more Pb-Free capable oven. We are still running a sister oven on
Electronics Forum | Mon Mar 29 11:51:55 EST 2004 | Claude_Couture
Hi all, Anyone familiar with BTU oven VIP-70. The control screen indicates that it is in IDLE mode. The recipe is running, but no heat is applied. The contactor for the heat is ON. All the electrical looks ok. I can't seem to be able to contact BTU,
Electronics Forum | Wed Jun 21 16:30:07 EDT 2006 | GS
Hi Dallen, I do not know BTU VIP70 oven, any way make sure if it is not yet wired for 480 V 3Ph (wiring diagram), may be it needs just to reset wiring on terminal block in order to run at 480V. Best if you ask BTU. If not, you have to buy a Transfo
Electronics Forum | Mon Nov 13 13:45:17 EST 2006 | russ
See now? all this talk here could easily be avoided by using vitronics!! hahahahahaha personally I think Heller and BTU both leave much to be desired. No, I do not work for vitronics OR fastek! hehe
Electronics Forum | Mon Jul 20 06:10:32 EDT 2009 | thanhnguyen
BTU ( VIP70A) lid will not close, during the weekend, we pop up to clean and vaccum, after done, try to close the lid, but not work. any input will be helpful. thanks
Electronics Forum | Sat Dec 10 22:31:16 EST 2016 | ecogroup
Hi Tom, We have a Paragon 150 with the FCU board problem. We are thinking about finding another board and swapping it . Did you get the ROM chips from BTU when you swapped the FCU board? Appreciate any advice. Thank you. Ray
Electronics Forum | Sat Nov 04 11:57:20 EST 2006 | joseluis_amper
Hello, I have an oven with a big fail. The Control Unit. It is a 5 zones oven (BTU VIP70)and has more than 10 years, and I think that now is not interesting to repair. I think to buy an offer, an oven Heller of 7 zones + cool,(better for lead free).
Electronics Forum | Mon Jun 26 03:56:44 EDT 2006 | slaine
hi I had a hunt round this morning and found all the schematic drawings for the vip70. Have you got a copy of them? where abouts in the uk are you im in Cumbria. drawing 5061617 appears to show some different wiring configerations, but im not sure if