Electronics Forum | Mon Oct 01 19:44:49 EDT 2007 | marcelll
Just bought a used VIP 98 and I have an alarm. Computer don't communicate with the embedded controler of the oven. I've check the cabling, OK, and there's power on the controler. The PC is booting normally. The controler is plug in the serial port 2
Electronics Forum | Mon Dec 17 12:12:18 EST 2007 | Claude_Couture
in very rare occasion I had problems with BTU ovens, I contacted BTU directly and they were always helpful.
Electronics Forum | Thu Sep 16 11:40:32 EDT 2010 | ccouture
Have you contacted BTU? They will be able to supply you with the setup files of your oven if you provide them with the serial #. Did you buy the oven used?
Electronics Forum | Fri Dec 22 09:19:11 EST 2006 | simonlee
Our VIP98 oven just refused to do anything this morning, no previous history of problems. Conveyor and heaters do not start up. None of the Solid State Relays in the back of the unit are operating, although we can make them switch by wiring up to t
Electronics Forum | Tue Oct 02 10:01:15 EDT 2007 | chrisgriffin
I once had a similar problem on a VIP98. The problem was with the FCU (furnace control unit). There was a burned IC on the lower left of the card. I don't remember what kind of part it was, only that it was very common and I got a new one from Dig
Electronics Forum | Fri Dec 07 02:10:26 EST 2007 | mpolak
Hi, Could you guys verify my BTU VIP98N oven settings for lead free process. At the moment as my standard profile im using these settings 140 160 180 207 205 220 257 same temps for bottom and speed 50cm/min. Has anyone got same oven and could
Electronics Forum | Thu May 26 21:07:22 EDT 2005 | KEN
This is caused by cte mis-match. The balls in the corners are short and fat. The balls near the null point are tall and more normalized. I don't remember what the zone settings were... BTU VIP98 BS was probably 22-25 IPM
Electronics Forum | Tue Jun 07 05:15:45 EDT 2005 | blueflag
Help Please could anyone advise when we run shutdown after 45 mins it should shut off . But we are still left with conveyor running also fans . regards Colin
Electronics Forum | Tue Jun 07 22:01:56 EDT 2005 | KEN
run shutdown.rcp after 45 minutes computer will load shutoff.rcp. Is this file not being loaded? If yes, then you have not defined the shutoff event in the scheduler. Poke around in the scheduler. Or check out the software manual. someone probab
Electronics Forum | Mon Sep 19 04:27:47 EDT 2005 | dougs
Check your power supplies, we had same fail a while back on VIP98 faulty power supply was the cause