Electronics Forum | Sat May 29 14:03:18 EDT 2010 | padawanlinuxero
Hello guys! I have a problem I had to change the MI Board on a MYDATA TP9-4 machine because it was firing 3 or more feeders at the same time, after the change it run great but then for some reason after a while it start to show an error message that
Electronics Forum | Fri Feb 21 10:50:00 EST 2020 | tomdegas
I am getting the following error on our MY9 during hardware initialization: F-MOT-MSEDYN HYDRA Z/156 Motor Timeout After the Theta test, The HYDRA head moves slowly all the way to the bottom and then moves slowly back up and the system fails initia
Electronics Forum | Thu Mar 05 07:40:55 EST 2020 | tomdegas
I swapped the mi boards with ones from a working My12 machine and the same results. To recap my problem: On "Hardware Initialization" the center jaws open and close, the Hydra Theta belt moves back and forth, the Hydra head moves all the way down an
Electronics Forum | Thu Feb 15 20:16:59 EST 2024 | erici
thanks for the reply. The Step motor module at the head is defective, so when the machine does the reference run, it will give a timeout because the DP station and pick and reject stations are not working. I reckon if i disable the RV, maybe i can
Electronics Forum | Fri Mar 22 03:19:43 EDT 2019 | bukas
well, in video shown it looks like #1 motor drives head #1 upwards but does not detect home sensor being triggered. and then you get timeout error, head not being able to reach the position ( machine not registering it has reached position). since yo