MYDATA TP9-4 MI board

Electronics Forum | Sat May 29 14:03:18 EDT 2010 | padawanlinuxero

Hello guys! I have a problem I had to change the MI Board on a MYDATA TP9-4 machine because it was firing 3 or more feeders at the same time, after the change it run great but then for some reason after a while it start to show an error message that

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Feb 21 10:50:00 EST 2020 | tomdegas

I am getting the following error on our MY9 during hardware initialization: F-MOT-MSEDYN HYDRA Z/156 Motor Timeout After the Theta test, The HYDRA head moves slowly all the way to the bottom and then moves slowly back up and the system fails initia

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Thu Mar 05 07:40:55 EST 2020 | tomdegas

I swapped the mi boards with ones from a working My12 machine and the same results. To recap my problem: On "Hardware Initialization" the center jaws open and close, the Hydra Theta belt moves back and forth, the Hydra head moves all the way down an

Siplace F5

Electronics Forum | Thu Feb 15 20:16:59 EST 2024 | erici

thanks for the reply. The Step motor module at the head is defective, so when the machine does the reference run, it will give a timeout because the DP station and pick and reject stations are not working. I reckon if i disable the RV, maybe i can

Samsung CP 45 NEO, servo motors

Electronics Forum | Fri Mar 22 03:19:43 EDT 2019 | bukas

well, in video shown it looks like #1 motor drives head #1 upwards but does not detect home sensor being triggered. and then you get timeout error, head not being able to reach the position ( machine not registering it has reached position). since yo