Full Site - : calibrate cam mirae (Page 11 of 14)

Calibration of Nozzle Holes on Mirae Mx350

Electronics Forum | Mon Jan 13 08:35:51 EST 2020 | griinder

The holes are calibrated in MSetup. Generally, I have never had luck using the auto teach for the nozzle changer. We would teach them each manually. Before doing this, you need to narrow your issue down a bit more. Which head gives you this error?

cp6 missing small parts

Electronics Forum | Tue Jan 31 03:34:50 EST 2006 | chadnugent79

If you are sure that your part data is correct, have you checked the calibration of Z origin? Are the parts leaving an impression on the paste or is there no indication of an attempted place. How small of resistors are we talking 0402, 0603, 0805?

Fuji CP-6 Feeder Maintenance Programs

Electronics Forum | Mon Oct 22 10:47:32 EDT 2007 | cyber_wolf

You absoultely must have a calibration jig. You should be able to justify this on downtime alone. Make sure your take up axles and white rollers are squeeky clean on the 12's. Also make sure that they are not running the cam speed too fast. We do no

Mirtec MV-7 Cam

Electronics Forum | Fri Nov 04 08:33:58 EDT 2011 | emeto

Hi, On the camera itself you should have an adjustable lens. You should be able to adjust it from there by hand. If you don't have it you should move camera up or down(I don't recommend that). the best thing is to see in your manuals if there is a wa

QP-132E // FCM 2

Electronics Forum | Sat Apr 20 07:44:01 EDT 2002 | Bob

I heard from a second hand source that the heads required calibrating reqularly and to do that they needed to be sent to the manufacturers. I also heard that they were fairly unstable and broke down alot. All these were not from first hand experian

Pick Up Error

Electronics Forum | Thu Aug 12 14:55:08 EDT 2004 | johnw

Hi guys I havnt been on for a while so its nice to be back been working in europe mostly Fuji CP6 skewing rnets Marcels comment is the closest rnets are a problem as said before the main areas are 1 A good assmbley shape is a must with 30% defaul

Contact Systems Vision Codes

Electronics Forum | Tue Nov 25 05:40:52 EST 2008 | wanderson

Calibration menu and then Index Cam Setup and follow the on screen instructions. (You can skip the focus step if you have not adjusted the camera's) The point you need to pay particular attention to is when it displays the intensity histogram, this

Another F4G/MCS30 question

Electronics Forum | Mon Jan 21 11:28:28 EST 2013 | dhopps

The machine will have to be reset-started to wipe the current proper and status out of the machine before you can communicate with an MCS. This can be dangerous if you do not have a current paper copy or disk back-up of your proper because you will

Calibration of feeders

Electronics Forum | Tue Aug 17 08:36:01 EDT 2004 | rlackey

CP6/7 feeders are mechanical indexing machines, and the springs, cams etc wear over time leading to misfeeds & increased attrition. You can just strip & repair but especially on the 8x2 feeders the pick up position is critical. John, I'd check with

CP6 Maintenance

Electronics Forum | Thu Mar 30 19:25:26 EST 2006 | daxman

I bet my bicepes are bigger than yours. Just kiding. I do appreciate the help and advice each one of you gave. I should also mention that during the production cycle, our cp6 gets to a point where it kind of just stops...almost like it's thinking...


calibrate cam mirae searches for Companies, Equipment, Machines, Suppliers & Information

PCB Handling Machine with CE

Stencil Printing 101 Training Course
Solder Paste Dispensing

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
Global manufacturing solutions provider

World's Best Reflow Oven Customizable for Unique Applications
Online Equipment Auction of Altronic: Small-Batch Surface Mount & Assembly Facility

High Precision Fluid Dispensers
PCB Depanelizers

Low-cost, self-paced, online training on electronics manufacturing fundamentals