Full Site - : calibration mydata (Page 2 of 10)

AdoptSMT will show many new product and service offerings at the Southern Manufacturing Show Farnborough, February 2014, Booth J45

Industry News | 2014-01-24 16:51:33.0

At Southern Manufacturing 2014 AdoptSMT UK Ltd., member of AdoptSMT Group, will again present many new products for the European PCB Assembly Industry. The supplies, services and consultancy offered by AdoptSMT Group are focused around the aim to keep the customers production running.

AdoptSMT Europe GmbH

Hover-Davis and Nortec to demonstrate new feeder and identification solutions at SMTAI.

Industry News | 2017-09-13 14:19:50.0

Hover-Davis will be exhibiting its latest feeder and identification solutions in Universal Instruments’ booth # 223 at SMTA International Electronics Exhibition on September 19-20 at the Donald Stephens Convention Center in Rosemont, Illinois near Chicago.

Hover-Davis

Hover-Davis and Nortec ID to demonstrate new feeder and identification solutions at SMTA International Electronics Exhibition

Industry News | 2018-10-11 16:59:19.0

Hover-Davis, the global leader in the design and manufacture of electronic component and media delivery solutions has expanded its partnership with Nortec ID, the auto-apply materials and identification management specialists.

Hover-Davis

Hover-Davis announces its 30 Year anniversary, displays new feeder and material automation solutions at SMTA International

Industry News | 2019-08-27 11:48:35.0

Hover-Davis, the global leader in the design and manufacture of electronic component and media delivery solutions, will celebrate its 30 year anniversary at SMTA International Electronics Exhibition on September 23-26 where it will display its latest feeder and material automation solutions

Hover-Davis

Mydata - Level too high in pick

Electronics Forum | Tue Aug 28 11:03:40 EDT 2012 | mikesewell

The problem is still intermittent. It has a new MIDAS head, installed and calibrated by Mydata, FWIW. Usually we work around it by moving parts upstream (Fuji AIM). I'll post an update when I finally chase the issue down.

MyData TP9-UFP : Optical Centering Calibration Question

Electronics Forum | Fri Oct 17 12:48:59 EDT 2014 | cyber_wolf

The only reason you would need to run this calibration is if the camera was replaced or the centering camera got whacked which is highly unlikely. If your placements are off, put an offset in the parameter file.

FUJI Line vs MY15 line

Electronics Forum | Fri Jun 10 09:08:09 EDT 2005 | ??

Sounds to me like someone had some mydata's and didnt know exactly how to calibrate them.....then that somebody purchased some brand new fuji's that were calibrated perfectly (which they should be when brand new) and that would be the difference. I h

MyData TP9-UFP : Optical Centering Calibration Question

Electronics Forum | Fri Oct 17 09:38:07 EDT 2014 | rgduval

Are you able to turn off mechanical centering? Or can you adjust the settings?

MyData TP9-UFP : Optical Centering Calibration Question

Electronics Forum | Thu Oct 16 12:35:03 EDT 2014 | upguy

We have tpsys 1.5.18 on our TP9-UFP. We are attempting to run "Optical Centering Calibration". Following the instructions in the manual, we have centered the cross hairs on the camera frame, loaded a "base" board then the L-19-447 calibration boar

Agilis Feeders

Electronics Forum | Mon Apr 29 17:19:34 EDT 2002 | Jimmy

The Agilis feeders perform as advertised after having them in use for several months. They significantly reduce the time it takes to load and unload feeders and don't require maintenance and calibration (unlike traditional feeders and the older Mydat