Industry Directory: component storage relative humidity (14)

StorageSolutions

Industry Directory | Manufacturer

Storagesolutions' automatic and intelligent component storage systems ensure a reduction of more than 50 percent setup time for pick-and-place equipment, complete certainty of the availability of the

SMT Dry Cabinets by Eureka Dry Tech

Industry Directory | Consultant / Service Provider / Manufacturer

Eureka Dry Tech's IPC/JEDEC J-Std-033c Ultra Low Humidity Dry Cabinets provides moisture/humidity controlled storage of MSD,PCB, IC packages. Drying technology trusted by millions in replacing baking, nitrogen & desiccant packs.

New SMT Equipment: component storage relative humidity (120)

Eureka Dry Tech XDC-2001 <5%RH Ultra Low Humidity SMT Dry Cabinet

Eureka Dry Tech XDC-2001 <5%RH Ultra Low Humidity SMT Dry Cabinet

New Equipment | Board Handling - Storage

Eureka XDC-2001 Fast Super Dryer Ultra Low Humidity Dry Cabinet Specs http://www.eurekadrytech.com/fast-super-dryer/xdc-2001 Anti-static Glass, Anti-static Paint on Body and Shelves, ​Anti-static Caster / Stands, 1 M ω Ground Wire Capacity: 1314 L

SMT Dry Cabinets by Eureka Dry Tech

Eureka XDC-1001 Fast Super Dryer Ultra Low Humidity Dry Cabinet

Eureka XDC-1001 Fast Super Dryer Ultra Low Humidity Dry Cabinet

New Equipment | Board Handling - Storage

Eureka Dry Tech XDC-1001 Fast Super Dryer Ultra Low Humidity Dry Cabinet Specs: http://www.eurekadrytech.com/fast-super-dryer/xdc-1001 Capacity: 657 Liters Humidity Range: LESS THAN 5% Recovery Time: Recovers to ≤ 5% RH within 30 minutes after acce

SMT Dry Cabinets by Eureka Dry Tech

Electronics Forum: component storage relative humidity (95)

Required humidity for SMT production and storage

Electronics Forum | Thu Apr 12 00:56:20 EDT 2007 | Jani

Our SMT production and storage area is air-conditioned, constant temperature is maintained but the humidity is not controlled , the raw SMT material is stored in a "Drier" cabinet, but since we assemble hybrid SMT and thru-hole PCB assemblies, the SM

Required humidity for SMT production and storage

Electronics Forum | Thu Apr 12 13:04:47 EDT 2007 | slthomas

Handling requirements of all classifications of moisture sensitive devices is found in J-STD-033. It really isn't an issue for most parts unless they're going to reach reflow temperature again, which is unlikely unless you're removing a nearby compo

Used SMT Equipment: component storage relative humidity (9)

Omron VT-S720-A

Omron VT-S720-A

Used SMT Equipment | AOI / Automated Optical Inspection

OMRON AOI VT-S720-A MACHINE Hardware Configuration Image signal input unit Main unit Power supply Air Camera Illumination Image resolution Feed method Line height PCB carrier width adjustment Ambient operating temperature Ambient opera

Qinyi Electronics Co.,Ltd

Omron VT-RNS2-L

Omron VT-RNS2-L

Used SMT Equipment | AOI / Automated Optical Inspection

OMRON AOI VT-RNS2-L Omron AoiVT-RNSⅡ parameters Hardware part LSIZE Image signal input part Camera 3CCD camera Lighting series Ring LED (R.G.B) Image resolution 10, 15, 20um Mechanism part Transmission method Belt transmission method Producti

Qinyi Electronics Co.,Ltd

Industry News: component storage relative humidity (193)

2002 NEMI Roadmap Points to Areas of Opportunity for Industry

Industry News | 2003-04-07 10:16:38.0

Portable Products and Optoelectronic Applications Still Hold Promise for Growth

SMTnet

How to Prevent Solder Ball and Bridging Defects during the SMT Reflow Process

Industry News | 2018-10-18 08:32:52.0

How to Prevent Solder Ball and Bridging Defects during the SMT Reflow Process

Flason Electronic Co.,limited

Parts & Supplies: component storage relative humidity (1)

Fuji Fuji splice tape

Fuji Fuji splice tape

Parts & Supplies | Pick and Place/Feeders

This splice tape is used for jointing carrier tapes in the SMT process, It is made of 2 silver tapes and release paper. Size: 8mm, 12mm, 16mm, 24mm Main Characteristic 1, Peeling-off force(N/25mm)by angle of 180 degree. 2,Retaining(H/25*25mm)

Qinyi Electronics Co.,Ltd

Technical Library: component storage relative humidity (7)

What is humidity control dry cabinet?

Technical Library | 2019-05-17 01:50:39.0

Dry cabinet is especially designed with fully automatic humidity control to prevent moisture related defects. This cabinet is the optimal storage expert for SMT/BGA/PCB/IC electronic components.Our newly developed design greatly increases dehumidifying system which runs faster and more reliable compare to those traditional dry cabinets. it decreases the defective rate at production line.

Symor Instrument Equipment Co.,Ltd

Symor ESD storage dry cabinet(Working principle)

Technical Library | 2019-04-08 23:21:29.0

Climatest Symor® adopts molecular sieve to dry air, the whole system is controlled by microcomputer, when humidity is high, It will start to absorb moisture,when the humidity reach the pre-set value, it will stop absorbing, and then discharge the water to outside the cabinet by heating,again and again by automatic control. The most effective and environment-friendly moisture-absorbing desiccant is molecular sieve, molecular sieve is the microporous crystal material synthesized by silicon and aluminium oxide. In order to keep the crystal net discharge to be zero, atoms with cations are located in the crystal structure.and the cation used in these synthetic crystals is usually sodium. At present, there are two kinds of molecular sieves widely used in the dry box industry: Class A and Class X. Molecular sieves are synthesized, shaped and activated under strictly controlled production processes. The whole controlled sythesis process can ensure consistency of the three-dimensional pore size. 3A molecular sieve pore size is 3 angstroms, 4A molecular sieve pore size is 4 angstroms; 13X molecular sieve pore size is 8.5 angstroms. The working principle of molecular sieve: Molecular sieves adsorb molecules onto the crystal surface by physical attraction force. Since 95% surface area of the molecular sieve is within aperture,it needs to screen the adjacent molecules by different size. Only small size molecules can enter into the inner adsorption surface of the molecular sieve through the crystal aperture. This selective adsorption phenomenon is called molecular sieve effect. The molecular sieve adsorption capacity and charge density (polarity) are further related to the adsorbed molecules. The molecular sieves can further distinguish which of the mixed molecules can be adsorbed and determine to what extent the charge density can allow the molecules to be adsorbed onto the crystal. Water molecules are particularly small (2.6 angstroms), that belong to highly polar molecules (very strong positive and negative electron density), and are easily adsorbed by molecular sieves, even under very low moisture condition,once the water molecules are adsorbed,they will be firmly fixed on the crystal. The environment-friendly moisture absorption device is equipped with molecular sieve. When it’s absorbing, the memory alloy controller is in tensile state, and the spring is in contractive state,which just make the valve contact the outer baffle, this insulates the outside air from inside dry box air to achieve dehumidification purpose; and after molecular sieve absorbed moisture inside dry box and become saturated, the program will automatically control the memory alloy device to shrink it so that the valve reaches the inner baffle position. Meanwhile, due to the shrinkage of the memory alloy, the spring is stretched and the valve is pulled out of the outer baffle,so that the moisture in molecular sieve will be discharged into the outside. after the dehumidifying process finished, the program automatically control and reset the memory alloy and spring,to restart absorbing status.

Symor Instrument Equipment Co.,Ltd

Videos: component storage relative humidity (28)

The Humitector™ Type 2 Humidity Indicator Cards, are non-reversible,  halogen-free, and cobalt dichloride free.  For use in dry packing, dry pack, of MSD's moisture sensitive devices, or SMD's surface mount devices.

The Humitector™ Type 2 Humidity Indicator Cards, are non-reversible, halogen-free, and cobalt dichloride free. For use in dry packing, dry pack, of MSD's moisture sensitive devices, or SMD's surface mount devices.

Videos

A Sustainable Alternative - Humitector™ Type 2 cards are halogen-free and cobalt dichloride free. For more information on Type 2 Humidity Indicators, visit https://www.clariant.com/solutions/products/2017/10/31/00/12/humitector-type-2-nonreversible-

Clariant Cargo & Device Protection

Aull Automatic Inline V-Cut PCB Depaneler

Aull Automatic Inline V-Cut PCB Depaneler

Videos

Full Automatic V-cut PCB Depaneler Introduction: This equipment can further improve the quality of depaneling. It can realize V-groove XY two-way automatic cutting, cutting aluminum & FR4 boards without burr, can connect the assembly line to realize

Winsmart Electronic Co.,Ltd

Events Calendar: component storage relative humidity (1)

How to Minimize Humidity Interaction with PCBAs for Robustness

Events Calendar | Tue Aug 18 00:00:00 EDT 2020 - Tue Aug 18 00:00:00 EDT 2020 | ,

How to Minimize Humidity Interaction with PCBAs for Robustness

Surface Mount Technology Association (SMTA)

Career Center - Jobs: component storage relative humidity (3)

Memory Architect/Product Engineer

Career Center | San Jose, California USA | Engineering

Company: Ma Labs Inc. Headquartered in San Jose, as a leading PC component distributor & rank #5 DRAM manufacturer in the worldwide, Ma Labs Inc. has specialized in memory modules since 1985. We provide a full range of memory modules from RDRAM, DDR

Ma labs

VP of Quality

Career Center | Orange County, California USA | Quality Control

Job Description: Summary: Reporting to the COO/CTO the VP of Quality role will involve creating and/or augmenting the Quality system and programs to be a pro-active vs. a reactive structure. This will involve creating an overall quality vision, se

STEC, Inc.

Career Center - Resumes: component storage relative humidity (5)

smt operator,technician,Field service engineer

Career Center | Sta. Rosa, Philippines | Maintenance,Production,Technical Support

Complete knowledge in smt,aoi and reflow. 11 years working experienced in production and 5 years experienced in the field service job.

Smt technician/operator

Career Center | Sta. Rosa, Manila Philippines | Technical Support

I am in the field of smt equipment for 15 years already and at present i am working as a Service Engineer for High Speed mounter machines . Our Company is solly Sales & Service providers of all pcb assembly and semiconductor equipment. I do inter

Express Newsletter: component storage relative humidity (1024)

Partner Websites: component storage relative humidity (161)

What is the function of the temperature and humidity sensor in Lyra Reflow Oven? - I.C.T SMT Machine

| https://www.smtfactory.com/What-is-the-function-of-the-temperature-and-humidity-sensor-in-Lyra-Reflow-Oven-id44562477.html

the solder on both sides of the component is melted and then bonded to the motherboard. The advantage of the Lyra Reflow Oven temperature and humidity sensor is that the temperature is easy to control, oxidation can be avoided during the welding process, and the manufacturing cost is easier to control

Shelf Life of Soldered Components - EPTAC - Train. Work Smarter. Succeed

| https://www.eptac.com/ask/shelf-life-of-soldered-components/

component storage, environment used to store component until soldered, and handling methods used on the component until soldered. Solderability of component leads is included in EIA/IPC/JEDEC J-STD-002D Solderability Tests for Component Leads, Terminations, Lugs, Terminals and Wires


component storage relative humidity searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next
SMT feeders

World's Best Reflow Oven Customizable for Unique Applications
Win Source Online Electronic parts

High Precision Fluid Dispensers
Fluid Dispensing, Staking, TIM, Solder Paste

Software for SMT placement & AOI - Free Download.