Electronics Forum | Mon Jul 28 11:22:46 EDT 2008 | blnorman
Iagree with Matt, normally caused by pad surface contamination. Out of curiosity, what is the PCB metallization?
Electronics Forum | Wed Nov 04 09:47:25 EST 2009 | tstrat
It was 7 wt% according to the EDS spectrum at the EN layer near the ball-pad interface.
Electronics Forum | Thu Jul 22 16:30:59 EDT 2010 | dyoungquist
It is likely that the pads that will not solder have been contaminated. There is something on the surface that is preventing the solder from flowing.
Electronics Forum | Wed Aug 30 23:45:23 EDT 2006 | ppcbs
Since BGA's are sensitive to contamination in the plating process, I always do a simple solderability test whenever we receive a new batch of boards. Take a board from the batch, apply no clean flux on the BGA site, then try to tin the pads with a m
Electronics Forum | Wed Aug 30 23:45:40 EDT 2006 | ppcbs
Since BGA's are sensitive to contamination in the plating process, I always do a simple solderability test whenever we receive a new batch of boards. Take a board from the batch, apply no clean flux on the BGA site, then try to tin the pads with a m
Electronics Forum | Tue Apr 15 21:24:41 EDT 2008 | davef
We find it curious that: * Heat slug pad for Q19 didn't take solder, indicating a pad [board] solderability issue. * Signal termination pads for Q19 didn't flow well, indicating a poor thermal recipe or a pad [board] solderability issue. * Signal ter
Electronics Forum | Mon Feb 21 08:39:10 EST 2005 | pemnut
There are so many variables to this. It could be paste, pad size, contaminated components-pads, placement speed, component thickness being wrong in the program, dropping parts into the paste instead of placing them, component recognition ploblems. Is
Electronics Forum | Fri Jan 13 08:53:53 EST 2006 | chunks
Wave not touching the thru-hole part. Adhesive on the pad. Board mask smear on the pad. Ring contaminated. Ring not plated correctly.
Electronics Forum | Wed Dec 06 21:36:13 EST 2006 | davef
It's surprising that you have that much copper. Copper contamination of leadfree is usually tolerable up to 1%. So, the copper is moving from the pad to the solder ball. Right? If that's correct, the pad requires a buffer material between it and
Electronics Forum | Tue Jul 07 08:42:49 EDT 2009 | ewchong
kpm, you are probably right. under magnification those two pads show some exposed copper which means that they were contaminated or had insufficient solder paste before reflow.
Golden State is a contract manufacturer that makes wire harnesses, electromechanical assemblies (box builds, subassemblies, PCBAs, kits, etc.) and services (sorting, rework, value additive manufacturing engineering)
18220 Butterfield Blvd
Morgan Hill, CA USA
Phone: 5102268155