Electronics Forum | Tue May 25 10:11:42 EDT 2021 | starsanat
Hello to you all. we got a CP45FV-NEO machine. it shows image1 error and I have no idea what this is for. please help me through it
Electronics Forum | Mon Aug 31 15:39:18 EDT 2020 | jmelson
Yes, the rightmost VME board is the IO_DPRAM, and it also handles the front panel buttons and E-stop inputs to the computer(s). So, reseat the connectors on the front of that board. Also, there may be an interface board on the bottom left (called C
Electronics Forum | Sat Jun 05 22:07:50 EDT 2021 | danniedarko
Hi, I live same error 3 years ago. I can fix this problem. but need remote access by (AnyDesk) software. and have 50USDT cost. send access information dannie.darko@outlook.com
Electronics Forum | Mon Nov 26 02:09:55 EST 2018 | bukas
yes I am, today im going to try to load backup image on to HDD. this error occurs before any machine movement, so it might be SW error... at least I hope so
Electronics Forum | Fri May 21 17:41:01 EDT 2021 | jamesatqkits
Hello, This is my first time posting to this forum, or forums in general, so go easy on me. I have just acquired a CP45FV NEO, "My other car is a CP45FV NEO" anyways, when I try to put the machine into ready mode I get the error, [0006] I/O power
Electronics Forum | Wed Oct 12 02:44:38 EDT 2016 | bukas
hello, I have a problem with CP45FV Neo swing mirror. The mirror it self works fine, manually controlled it moves to correct position and back. While working it also moves properly but when machine is about to check for nozzle existence at the end of
Electronics Forum | Tue Mar 07 09:35:55 EST 2017 | buckcho
hello, I have a problem with CP45FV Neo swing > mirror. The mirror it self works fine, manually > controlled it moves to correct position and back. > While working it also moves properly but when > machine is about to check for nozzle existence a
Electronics Forum | Tue Feb 25 03:32:58 EST 2020 | bukas
hello guys, I got a problem with MAIN START switch on Samsung CP45FV NEO. The switch itself works, and it activates contactors #1-1 #1-2 and #3 but after pressing READY button there is en error msg reporting that MAIN START has not been pressed. Alre
Electronics Forum | Wed May 26 06:07:07 EDT 2021 | bukas
its not that you should never open it manually, it just can be a problem sometimes. CP45 have a few problems with data corruption and this can be one of them. just make sure you regularly backup disk, and dont delete old backups straight away.
Electronics Forum | Mon Aug 31 07:06:20 EDT 2020 | bukas
did you try to unslot all computer boards (both PC and machine)and put them back? sometimes they loose contact and make wacky errors...