Why salt spray chamber fail to spray salt mist?

Technical Library | 2019-11-20 22:44:25.0

Salt spray test chamber is used to test teh salt corrosion resistance ability of hardware, metal and other auto parts,the chamber can quickly detect the corrosion resistance degree of products in the temperature, humidity and salt spraying environment, which can effectively improve production efficiency. So what is the reason why such a salt spray test chamber does not spray? As per our past maintenance experience,there are below reasons,customers can have a look,hope it is helpful: 1, the spray tower is blocked; 2, water pipes clogged, water flow can not go in; 3, the air compressor stops running,pls open the air compressor button; 4, main switch of the air compressor outlet is not turned on,pls turn on. 5, the solenoid valve fails, the pressure meter is broken or the pressure is too low, pls check with Climatest and repair it. 6, when the nozzle is clogged, the nozzle should be carefully removed and cleaned,because it is fragile. 7, if the spray pressure is normal, the position of the nozzle glass is also correct, but what is the reason for not spraying? In this case, it is necessary to carefully observe whether there is dirt at the contact surface of the nozzle. If so, clean up the dirt and the spray can be carried out normally. That‘s all we‘re going to talk about today. If you have any questions, follow us on facebook, Please feel free to ask us questions.

Symor Instrument Equipment Co.,Ltd

Aqueous Technologies to Exhibit Its Flagship Trident System at IPC Midwest

Industry News | 2012-07-25 10:11:23.0

Aqueous Technologies Corp will highlight its flagship Trident system – the Trident LD – in Booth #103 at the upcoming IPC Midwest Exhibition & Conference

Aqueous Technologies Corporation

Aqueous Technologies to Exhibit Its Flagship Trident System at SMTA International

Industry News | 2012-09-12 16:42:37.0

Aqueous Technologies Corp. will highlight its flagship Trident system – the Trident LD – in booth #227 at the upcoming SMTA International Conference and Expo,

Aqueous Technologies Corporation

Solder Joint Reliability

Industry News | 2018-10-18 08:49:15.0

Solder Joint Reliability

Flason Electronic Co.,limited

SMT Dictionary – Surface Mount Technology Acronym and Abbreviation

Industry News | 2018-12-08 03:29:29.0

SMT Dictionary – Surface Mount Technology Acronym and Abbreviation

Flason Electronic Co.,limited

CP6-4000 nozzle centering errors?

Electronics Forum | Fri May 30 08:24:08 EDT 2008 | cyber_wolf

The nozzles get centered at zero degrees and 180 degrees. I believe the yellow asterisk is the measurement at zero degrees, when it rotates to 180 is when you will get a red X or a green O. (In other words the yellow asterisk is normal) I think you

CP6-4000 nozzle centering errors?

Electronics Forum | Thu May 29 14:57:26 EDT 2008 | rodrigo

Hi all, Is it normal for some of the small nozzles to be rejected by the wide view camera? Every time I do a nozzle centering the narrow view camera shows green circles for nozzles 1,2,3,4. The larger ones (5 and 6) show the asterisk. The wide view c

CP6 pickup errors

Electronics Forum | Fri Feb 25 16:34:53 EST 2005 | jimmyb

In your PDs you must specify a single nozzle size. Meaning don't assume that entering nozzle size max=1.3 and nozzle size min=1.3 forces the machine to use a 1.3. Nozzle size min is not used in the CP6 software (it only uses nozzle size max), there

Fuji CP6 Issues, Questions

Electronics Forum | Thu Jun 14 16:31:38 EDT 2007 | aj

I concur Chunks ! A simple test to carry out is the Z0 height check across the board, with particular attention to the area of the board you are having problems. You should at least see the nozzle touch the board , ideally press the board slightly.

CP6 pickup errors

Electronics Forum | Mon Feb 28 08:34:46 EST 2005 | Alex

Good advises thanks. I'll go thru all nozzles and vacuum check today and tell the programer about PD's and nozzle vs shutter. Should I check at the same time all the vacuum filter ? For the placement test, we use the same feeder at the same position.