Full Site - : cp6 servo amp error (Page 21 of 35)

CP6-4000 nozzle centering errors?

Electronics Forum | Fri May 30 09:50:04 EDT 2008 | jdengler

Another sticky issue is that if you use after market nozzles especially mixed in with Fuji nozzles the Anti-Marking Illumination Disks can be different enough that the vision system will reject nozzles. Jerry

CP6-4000 nozzle centering errors?

Electronics Forum | Fri May 30 09:53:19 EDT 2008 | cyber_wolf

"Another sticky issue is that if you use after market nozzles especially mixed in with Fuji nozzles the Anti-Marking Illumination Disks can be different enough that the vision system will reject nozzles. Jerry " Thats what I meant when I said they

CP6-4000 nozzle centering errors?

Electronics Forum | Fri May 30 10:18:34 EDT 2008 | jdengler

I've had some that under normal light they looked the same but when the UV light hit them they were very different.

CP6-4000 nozzle centering errors?

Electronics Forum | Fri May 30 11:58:16 EDT 2008 | fredc

The right paper incorrectly applied can be a problem also. I have seen it on even new Fuji nozzles with the illumination disk bunched up on one side of the tube with a gap on the opposite side.

Fuji CP 642 Communication Cables with Flexa

Electronics Forum | Fri Jul 19 11:16:21 EDT 2019 | dman97

And yes if the proper data is not correct it will give you a error message because Flexa cannot communicate with the CP6.

CP6 Maintenance

Electronics Forum | Sat Jan 21 19:44:07 EST 2006 | vincent

i have a problem similar to Daxman where cp6 usually having problem when it run at high speed, the head seems to have problem returning back to its origin at st12 and stop at st15 and st19 for nozzle change error, when rotating the head by hand, some

Servo limit over

Electronics Forum | Thu Aug 18 11:38:34 EDT 2011 | johndoe0222

I got this error message on the fuji IP3: " Servo limit over. Servo Z1 Axis +" I was wondering how to fix this error. Thanks.

CP6 pickup errors

Electronics Forum | Fri Feb 25 16:34:53 EST 2005 | jimmyb

In your PDs you must specify a single nozzle size. Meaning don't assume that entering nozzle size max=1.3 and nozzle size min=1.3 forces the machine to use a 1.3. Nozzle size min is not used in the CP6 software (it only uses nozzle size max), there

Fuji IP-1 hesitates for a few seconds then continues working

Electronics Forum | Fri Mar 23 03:53:44 EDT 2007 | Guest

Hi Bert , I dont know much about IP , since I partnered our Fuji CP 6 with Siemens .At any rate, can you check your flat ribbon cable of your Ip's Head. I assume there one wire that is nearly breaking. During movement, head servo controller experie

Fuji CP 65 FRQ Servo Overflow

Electronics Forum | Fri Mar 02 18:44:43 EST 2018 | magergar

At boot there is an alarm that I can't get rid off Servo Alarm FRQ AXIS Servo Overflow I tried to calibrate it in mecha mode but the same error doesn't let me, it's there something I can do?


cp6 servo amp error searches for Companies, Equipment, Machines, Suppliers & Information