error 117:Overflow on CSM84

Electronics Forum | Sat Dec 01 18:08:03 EST 2007 | jmelson

Hello, I just ran into a crazy problem with my CSM84. I did a batch of one side of a board, then loaded the program to do the top side, and it stops with the head over the 3rd component's feeder, and reports error 117:overflow. The maintenance manua

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Tue Apr 02 14:56:30 EDT 2024 | kingkelvin

Hi all - my problem is a bit worse now - I can get all hydra tests to pass in extended service, except indicator levels at current 7 a bit high past 190 limit at ~210-220 - other than that hydra bank re-installs OK - but still it makes a bad hitting

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 19:32:09 EST 2020 | SMTA-Alex

The fact, that your Hydra head goes up and then starts moving slowly, means that it didn't find the limit. Since there are no mechanical obstructions and you swapped all the boards, the things to look at are cabling. Double check the ribbon cables fo

Universal Advantis Y1 axis error code 10201

Electronics Forum | Tue Jun 27 05:28:32 EDT 2023 | ttheis

We powered up our Advantis machine after leaving off for several months. When we powered it up went to zero it we get an error on the y1 axis during zeroing. Command move home: pattern step 0. The y negative limit is hit during homing, the axis then

Universal Advantis Y1 axis error code 10201

Electronics Forum | Fri Jul 07 17:17:43 EDT 2023 | ttheis

We swapped the Y1 and Y2 pc800 controllers with no change. We swapped out the UIMC III-I cards from another machine with no change. VRM amps all look OK, no errors. The machine moves the head both in the x and y directions during the zeroing attemp

Universal Advantis Y1 axis error code 10201

Electronics Forum | Fri Jul 07 17:33:25 EDT 2023 | jdengler

Since you haven't received any useful advise I will throw my 2 cents in. I do not know this machine but in general what you describe is an axis that does not get it's home pulse in time. Many machines will have an in-range sensor that gets flagged

Re: Floor Wire less strap

Electronics Forum | Mon Apr 19 13:17:00 EDT 1999 | Dave F

| Dear all | Considering Anti static precautions? | 1-Do we need to add a layer of ...say . Epoxy for the floor in our factory? | provided that .The current floor is hard top concrete of 250 Kg/cm2. | 2- Anti body heared about Wire less Hand strap So

Re: Driver problems on DIP insertion machine

Electronics Forum | Fri Sep 24 13:44:06 EDT 1999 | Eric Lee Williams

| | The machine is a Universal 6796 DIP inserter. The driver card for the X axis burned a couple of resistors and a trace, probably a couple of power transistors too. I had a spare card and put it in. Now on powering-up the machine, the X-Y table

Re: Driver problems on DIP insertion machine

Electronics Forum | Fri Sep 24 20:33:44 EDT 1999 | Ron Gillam

| | | The machine is a Universal 6796 DIP inserter. The driver card for the X axis burned a couple of resistors and a trace, probably a couple of power transistors too. I had a spare card and put it in. Now on powering-up the machine, the X-Y tabl

Mirae MX200L

Electronics Forum | Thu Jun 29 18:13:00 EDT 2023 | bobpan

here is the error.....looks like plus limit error