Electronics Forum | Mon Jan 08 19:52:14 EST 2007 | fastek
A soft limit error is an error due to trying to drive the head outside it's mechanical limits. Check your X-axis program data for this part.
Electronics Forum | Wed Dec 07 02:35:28 EST 2011 | mk15
Hi, I am looking for help with Error Philips Comet, Start Procedure -OK, INTIAL SERVO ORIGIN -OK, AUTORUNNING -OK, PCB START -OK, FIDUCIAL -OK, PICKUPCOMPONENT -OK, NEXT-ERROR E2 CORRECTION DATA ERROR(CORRECTION DATA IS NOT LOADED OR FAILED TO ADJU
Electronics Forum | Fri Feb 15 13:45:18 EST 2013 | cowens
We have a MPM UP2000. We are getting a hardware limit error when we turn the machine on and try to reset. The F14 fuse blows every time we replace it. The downstop is the first axis that it tries to go through but we get this error. Any help would be
Electronics Forum | Sat Sep 18 08:55:46 EDT 2010 | joetfree
Hi All, i have io head unit kv8-m4570 with error: limit error. if you have operation manual or suggestion, please help us Thanks
Electronics Forum | Thu Oct 21 11:15:00 EDT 2010 | jorge_quijano
Do you know in which axis the problem occurs? usually when "hardware limit error" shows is because one of the axis touches the sensor of the limit, this is to prevent the mechanism hit something, If you machine is used, you can check if there is a mi
Electronics Forum | Wed May 02 09:14:08 EDT 2007 | stefi
Hi, We have a very annoying problem with a Philips Orion 2 SMT machine. It displays the error message "Second Limit Over" a few times per shift and it's impossible to make the machine work again unless it is turned off from the mains. It stops in th
Electronics Forum | Tue Feb 09 09:18:13 EST 2010 | davemacnemo
Machine installer gave me some tips and a run through the software. Everything worked just fine. First solo attempt to run product that we started with gives L305 SoftLimitOver... error after picking first components and passing over camera. Additio
Electronics Forum | Thu Jan 19 18:11:45 EST 2023 | atpico
My UP2000 HiE Printer on Power-ON during initial Reset will show this error and reset will abort with no way to continue. E00938 10 - HARDWARE LIMIT WARNING In Input/Output Screen all Sensors are in normal situation and will react normally when t
Electronics Forum | Tue Mar 06 13:39:49 EST 2018 | GTune
Hello everyone, I am having trouble with our UIC VCD through-hole pick and place machines. It has been sitting around for several years now and I had to replace half the gaskets in the machine which werecausing slow movement. I'm getting an error mes
Electronics Forum | Wed Dec 14 15:49:30 EST 2005 | derengmao
I did calibration for the fixed camera according to the Training Center System's book. But it seemed it is for diciding the heads'offset, very few is for camera itself. When calibrate, It does recognize the calibration tool ad finish. However when te