MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Tue Apr 02 19:13:02 EDT 2024 | mistrthou

Nice. BTW, I found a pic online. https://www.flasonsmt.com/Uploads/6528ca4e9c5b7.jpg I'm surprised it doesnt have that stuff underneath the machine behind the large panels. Thats where we kept ours.

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Mon Apr 08 18:16:20 EDT 2024 | mistrthou

We had a Mycronic tech in adjusting rings to get us within spec. He was saying the emitter/receiver board at the top and the tubes themselves can go bad. Between that and having weak latches, we're looking at a refurbished unit. But we're rocking a M

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 14:28:26 EDT 2024 | kingkelvin

We have MY9 - when it changes hydra tooltips - most of the time it makes a small "hitting" type noise - with error F-MOT MOVESLOWMOVE HYDRA Z/205 - however you can just hit continue and it will always change the tools and finish the board - I've un-i

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 17:00:32 EDT 2024 | kingkelvin

For the hydra camera z-level - there is short section in manual - mentions using metal ruler to cover the camera - but for the other cal steps - I see nothing in the manuals for instructions - so I don't know if any special jigs are needed? I don't h

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Mon Apr 08 14:07:25 EDT 2024 | kingkelvin

Hello all - so I got in the calibrate plate for hydra tool offsets - it completed the calibration - I then installed the first row of white tips with the menu - and the machine still does same thing it puts the tips away but makes a hitting type nois

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Mon Apr 08 15:07:56 EDT 2024 | tey422

To me, it seems like there are slightly XY offset. Hydra might be able to pick up the tips, but not all the way securely attached to the hydra tubes. So, when the tips put back are not fully seated, which causing the tool stick inside the bank. You

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Mon Apr 08 15:47:07 EDT 2024 | kingkelvin

Hi all - all good info thanks, so my indicator levels are a bit off which I knew - but I didn't realize that might be the source of this problem - after speaking with PFI and realizing the next step is to get the indicator levels to the 190 range (ma

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Mon Apr 08 17:27:36 EDT 2024 | kingkelvin

I found a 0.9mm hex tool - but if I adjust the indicators "all the way up" on the shaft I get all current ranges at 255 (so obviously too high on the shaft) but if I place it anywhere else on the shaft (slightly down from top, or all the way down as

Yamaha CSM84VZ error code 79

Electronics Forum | Thu Oct 06 11:18:47 EDT 2011 | tpappano

That message is what you get if for example, if you press "stop" while a board is being placed. While "interrupted" you can for example, press "exit", go make adjustments to mount data or whatever, return to "running", then the board program, then p

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Tue Apr 02 14:56:30 EDT 2024 | kingkelvin

Hi all - my problem is a bit worse now - I can get all hydra tests to pass in extended service, except indicator levels at current 7 a bit high past 190 limit at ~210-220 - other than that hydra bank re-installs OK - but still it makes a bad hitting