Full Site - : data power error mydata (Page 33 of 47)

MyData Y wagon shudder

Electronics Forum | Thu Mar 10 23:23:56 EST 2005 | pmd

We have a MyData TP-9-2 with a in line Y wagon. It is a long screw and the vintage is 1994. The Y wagon vibrates at about 24 micrometers at about 25 hertz. Burnin reviels zero encoder pulse errors. Hystersis test indicates a Y axis Y wise varance of

MyData TP9 dead?

Electronics Forum | Thu Feb 06 14:01:55 EST 2014 | rgduval

1. Fuse 2. Power Supply 3. Power Distribution card 4. Booster Start by checking all of the fuses on the front of the power supply (accessed by removing the front cover of the machine). Then, check all of the fuses on the first card in the MOT bay.

MyDATA 12e Machine blowing fuses when powered

Electronics Forum | Tue Jun 07 20:27:08 EDT 2022 | SMTA-64387687

The ribbon cables might be shorting. Have you replaced them?

MyData 12 errorF-TLMN-18

Electronics Forum | Wed Jan 17 14:39:14 EST 2024 | tomdegas

HELP. I DO NOT KNOW WHAT BIRIL IS. WHERE IS IT LOCATES

MyData 12 errorF-TLMN-18

Electronics Forum | Wed Jan 17 15:13:53 EST 2024 | mistrthou

tool installation >

Mydata installation

Electronics Forum | Thu Dec 03 12:40:47 EST 2015 | user

I just purchased a MyData SMT machine that > requires 3 phase 208V. I have 240 single phase > with a 3 phase power converter that outputs 240V > 3 phase. Should I be concerned about the > differences in voltages and if so how should I > solve th

MyData DPak not placing

Electronics Forum | Mon Jul 29 13:48:20 EDT 2013 | cyber_wolf

We have placed millions of DPAKS on our Mydatas without issues. Usually the crosshairs need to be just slightly to the right of the dimple when trimming. We do not use high centering force. Please tell us exactly what the error message is.

MyData 12 errorF-TLMN-18

Electronics Forum | Fri Jan 05 17:21:54 EST 2024 | tomdegas

The issue is with the Midas head. It gives me the same error with any tool I try to install.

MyData TP9 dead?

Electronics Forum | Thu Feb 06 12:32:24 EST 2014 | gnus

Hi all, During our last production run, our MyData TP9 machine shut down on its own mid assembly. Screen went blank. I turned off the power switch and waited 10mins before trying to power it up again. I turn the switch on and hear the fan turning on

Fuji IP3 Problem

Electronics Forum | Tue Aug 22 10:51:49 EDT 2006 | rmitchell

Hi, Hope your machine is back up and running. Are you sure it is not program or PD (part library) related? Try power off and back on and delete the machine program from the machine. Then- Power off and back on and see if the VP error is gone. It