Electronics Forum | Tue Dec 01 18:50:11 EST 2015 | lkovach
I just purchased a MyData SMT machine that requires 3 phase 208V. I have 240 single phase with a 3 phase power converter that outputs 240V 3 phase. Should I be concerned about the differences in voltages and if so how should I solve this issue.
Electronics Forum | Thu Jun 09 18:12:48 EDT 2022 | curtisp
These were all great suggestions and helped find the issue; we ended up replacing the Mot M board which made it work.
Electronics Forum | Tue Jun 07 19:04:07 EDT 2022 | proceng1
IF the two are identical, swap the suspected bad one (#2) position 1, and see if the fuse blows before connecting the second one. Basically the same test process you describe, but swap the units first. See if the problem follows the card, or stays
Electronics Forum | Tue Jul 17 09:10:28 EDT 2012 | dontfeedphils
You can enter the service program for the MyData, can't remember exactly how, you have to exit out of tpsys to the command prompt and type service or something along those lines. Then you can check the raw numbers for vacuum and force on the Midas h
Electronics Forum | Tue May 07 13:41:36 EDT 2013 | cyber_wolf
MOVFI is a theta error there are about 10 things that can cause it. Start with making sure you do not have an acceleration set to lowest while the others are at high or highest in the package data. Next look at ribbon cables...
Electronics Forum | Fri Jan 05 17:27:46 EST 2024 | rmrshield
Please clean the HEAD in BIRAL and put the NYK-2 Greese Solved thit issue
Electronics Forum | Wed Jan 17 15:07:34 EST 2024 | rmrshield
BIRAL is a HEAD cleaning oil it's not a overall HEAD clean the inside of nozele picker only
Electronics Forum | Fri Jan 26 16:38:15 EST 2024 | mistrthou
Do you get any errors during the tool install? Are you intalling all tools, all uninstalled tools? What if you try one single tool only (A12)?
Electronics Forum | Wed Dec 04 16:35:54 EST 2013 | martingruber
I am facing the following problem: Powering up the machine the start sequence stops with following message: Inizializing Hardware .... Reading SRAM data .... Inizializing MEI Motion Bd .... Mei bd. @ 240 # Dev. Version 2.4g2 Option 41 DSP BOOT MEMORY
Electronics Forum | Wed May 11 20:25:38 EDT 2022 | mikevb
Thanks. Yes, I replaced the ffx board with a new one and made sure everything is cleaned. I did check the flex cable connect as I removed all of that to test continuity between everything. It all checked out continuity wise. I also tried to disable t