Full Site - : data power error mydata (Page 37 of 47)

Philips Topaz X DOWNLOAD IO STN.DATA NG

Electronics Forum | Mon Feb 20 13:43:54 EST 2012 | acsscott

Having a problem at power up, that our Philips Topaz X displays "DOWNLOAD IO STN.DATA NG" in red. It times out after about 5 minutes, then comes up. When we try to find the origin, it gives an error that the "Head Down sensor is OFF". If we go int

MYData issue

Electronics Forum | Tue Jun 19 17:42:38 EDT 2007 | dyoungquist

We run a TP9 machine and had a very similar problem with it. On a TP9 machine there is a power supply board where all the voltages are generated. It is located on the bottom side of the unit. The problen was with one of the fuse holders. The co

Mydata M12 issue

Electronics Forum | Mon Oct 05 08:19:13 EDT 2009 | rgduval

We've been having random transducer errors on our TP recently. After speaking with MyData tech support, we were told the answer could be: 1. the transducer(s), 2. something causing undue friction, 3. something undiagonsed yet. Their recomendation

Re: S.P.C. For Pick Place (Smt)

Electronics Forum | Thu Aug 12 17:03:44 EDT 1999 | Brian Wycoff

| | Q.C. manager asking me about spc's for Mydata Pick & Place. | | Other then Visual inspection, is there other ways to automate | | placement inspction? | | | | Thanks | | | Sure! There are a few automated vision systems available today that co

Communication problem

Electronics Forum | Thu Aug 29 11:56:21 EDT 2013 | kdc45

Sent program to a CP43 and the part data was not recognized. Machine message to power down and back up, so we did so. On power up, screen appeared with the following: OS Error Err Code 0001 Err task 0028 Err para FFFF Ex stat 0151 Err adrs CC400000

MyData Missing Placements

Electronics Forum | Thu Jun 28 20:11:32 EDT 2007 | rfrog

Hi folks, I've been bouncing off of MyData technical support for some time on an issue with a MyData machine. Seems that this My9 likes to skip an 0402 placement at a rate of ~ 1000/million. Profile: MyData My9 Mechanical centering Midas only

MyData Missing Placements

Electronics Forum | Tue Jul 10 16:13:52 EDT 2007 | bk

Hi folks, I've been bouncing off of MyData > technical support for some time on an issue with > a MyData machine. Seems that this My9 likes to > skip an 0402 placement at a rate of ~ > 1000/million. > > Profile: MyData > My9 Mechanical ce

CP-642: What reset nozzles at start of nozzle centering?

Electronics Forum | Thu Mar 22 17:18:17 EDT 2018 | rodrigo

Hi all, Our (new/used) CP642 resets the nozzles heads first time I do a nozzle centering after power on. But we're getting errors st17 and st19 and while working on the sensors I noticed that it does not resets the heads before I start a nozzle cent

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 09:40:14 EDT 2014 | rgduval

I'm surprised MyData is pushing the service call. They're usually pretty good at walking you through some troubleshooting steps before going straight to the service call. So, the failure sounds like an encoder failure; the encoders are attached to

Mydata M12 issue

Electronics Forum | Mon Oct 05 10:29:38 EDT 2009 | cyber_wolf

I ended up finding that there were broken chords on the X-belt. I replaced it and all is good. Rob, Mydata is right. You can indeed end up spending lots of time and money trying to chase a transducer error. Things I would look at: 1. Lubing the X b


data power error mydata searches for Companies, Equipment, Machines, Suppliers & Information