Electronics Forum | Mon Jan 20 17:37:30 EST 2020 | sumote
Here is a picture of the inside of my machine. https://drive.google.com/file/d/1hsLLHz1ho867qcSf7AYUoivUUn8NFbH6/view?usp=sharing
Electronics Forum | Thu Jan 04 11:07:59 EST 2018 | ilavu
Ray, Did you solve this problem? I am having same error on same model machine. My problem is, when camera axis moves to look at the first fiducial, camera hits to the cleaner and error comes up with rising table error, camera axis not home. Even log
Electronics Forum | Thu Jan 04 21:38:27 EST 2018 | dekhead
Error is occurring during move to fiducial 1 position (from board stop position)? Or during move to board stop position (from park position)? What is error displaying onscreen? Did you also just replace belt(s)?
Electronics Forum | Thu Aug 27 03:19:21 EDT 2020 | dekhead
Have you done Squeegee Heights calibration? (no tools required) Does it complete cal routine without error? Does pressure compensate on next print, with corresponding squeegee, following acknowledgement of pressure error? The readings calibration, ge
Electronics Forum | Fri Jan 05 11:20:31 EST 2018 | dekhead
AC2 on MUX card).
Electronics Forum | Fri Jan 05 12:18:10 EST 2018 | dekhead
Does it happen in board stop move in diagnostics?
Electronics Forum | Fri Jan 05 14:58:36 EST 2018 | dekhead
Information sent to your email.
Electronics Forum | Fri Aug 28 09:27:08 EDT 2020 | serge_pirog
After 2-3 cycles error disappear.
Electronics Forum | Fri Aug 12 18:39:21 EDT 2022 | magsat
Hello, please help, On DEK 265 GSX I have on the monitor: "Downloading vision system" and then nothing happens (no error comes up)