Electronics Forum | Tue Sep 21 17:47:27 EDT 2010 | dman97
Yes, Sorry I meant the Y3 enclosure. Anyway Thanks to DEKHEAD and jamyboy for helping me out on this problem. You guys are great. Thanks again.
Electronics Forum | Mon Jul 30 17:31:59 EDT 2018 | dekhead
That error message is keyed by a hardware (soldered) link on the backplane board of the Y1 (motor controls), through direct cable to PCIB40#3... check connections both ehds; possibility of multiple PCIB failures?
Electronics Forum | Wed Aug 01 09:03:54 EDT 2018 | bukas
check 12PL14, 12PL16, 12PL17 connectors. also, there are few jumpers on backplane of Y1, check them too. a single broken wire can get you this error, so my bet is cables.
Electronics Forum | Tue Feb 18 06:29:04 EST 2020 | leeg
We are having a few issues lately with a Data file open error on the printer and also the belts carrying on spinning when the PCB has hit the board stop even though the board stop sensor is activated that it has seen the PCB, anyone seen these issues
Electronics Forum | Wed Mar 25 11:09:08 EDT 2020 | sumote
Have you measured and input the "Distance To Image" setting correctly? If that number is off, you will get that error.
Electronics Forum | Tue Mar 31 09:25:18 EDT 2020 | emeto
If you believe your picture is in the middle and is not skewed, than go to your basics and recheck your fiducial locations and detection. Sometimes these machines recognize something around and give you this error. Try program with isolated pads and
Electronics Forum | Mon Sep 20 14:23:50 EDT 2010 | dekhead
No, there is not a way to initialise into the diagnostics menu with the head raised / covers open. Literally lowering the head manually (prop head, disconnect actuator, etc) is naturally possible, but not receommended... and based upon your symptom
Electronics Forum | Mon Sep 03 04:05:56 EDT 2012 | omur
The issue has finally been resolved. It turns out that while checking the vision board, our engineers accidentally changed the address of the Analogue Board (which is adjacent to the vision board) - thus, leading to this startup error - with the unh
Electronics Forum | Sat Jun 05 09:24:40 EDT 2010 | dekhead
As stated, that error relates to rail lifted sensord (L & R)... Machine is perceiving that something is causing rails to lift at inappropriate time. You can monitor sensor status in Rising Table diagnostic to see that they are toggling appropriately.
Electronics Forum | Fri Sep 14 10:30:45 EDT 2012 | dekhead
I believe there was a software issue as well; Initially installed software (4.03) replacing existing 2.12. After that it got past the "Stack Overflow" and displayed the expected error for incorrect addressing on PCAD12... BTW solution to "vision boa