Electronics Forum | Fri Jan 05 14:58:36 EST 2018 | dekhead
Information sent to your email.
Electronics Forum | Fri Aug 28 09:27:08 EDT 2020 | serge_pirog
After 2-3 cycles error disappear.
Electronics Forum | Thu Jan 04 21:38:27 EST 2018 | dekhead
Error is occurring during move to fiducial 1 position (from board stop position)? Or during move to board stop position (from park position)? What is error displaying onscreen? Did you also just replace belt(s)?
Electronics Forum | Thu Jan 04 11:07:59 EST 2018 | ilavu
Ray, Did you solve this problem? I am having same error on same model machine. My problem is, when camera axis moves to look at the first fiducial, camera hits to the cleaner and error comes up with rising table error, camera axis not home. Even log
Electronics Forum | Thu Aug 27 09:29:04 EDT 2020 | serge_pirog
Yes, I calibrated the height, no error. How can I check that pressure was compensated? If we press button "continue" after some cycles of printing system will show "error".
Electronics Forum | Thu Aug 27 03:19:21 EDT 2020 | dekhead
Have you done Squeegee Heights calibration? (no tools required) Does it complete cal routine without error? Does pressure compensate on next print, with corresponding squeegee, following acknowledgement of pressure error? The readings calibration, ge
Electronics Forum | Fri Jan 05 03:32:46 EST 2018 | raymccomb
yes we resolved the engineer did not set the servo to zero so it did not know its datum start point.
Electronics Forum | Fri Jan 05 12:02:28 EST 2018 | ilavu
Camera works fine from home to ref. position to fiducial1 and 2. Problem shows up from home to board stop. AC voltage between AC1 and AC2 is 41.7 and during move it drops to 41.5.
Electronics Forum | Wed Nov 06 08:23:53 EST 2019 | dekhead
If it is always showing 5.0Kg as the "target" value on the error on the first print then yes there is a problem. Are you certain that it is accomplishing the requested (12Kg ?) on the prints thereafter? Does it do Heights calibration (no tools requir