Full Site - : dek 265 horizon fatal error (Page 3 of 5)

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 14:48:09 EST 2018 | ilavu

Yes.

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 14:58:36 EST 2018 | dekhead

Information sent to your email.

DEK HORIZON 265 Squeege Pressure question

Electronics Forum | Fri Aug 28 09:27:08 EDT 2020 | serge_pirog

After 2-3 cycles error disappear.

DEK 265 Horizon Servo Following Error

Electronics Forum | Thu Jan 04 21:38:27 EST 2018 | dekhead

Error is occurring during move to fiducial 1 position (from board stop position)? Or during move to board stop position (from park position)? What is error displaying onscreen? Did you also just replace belt(s)?

DEK 265 Horizon Servo Following Error

Electronics Forum | Thu Jan 04 11:07:59 EST 2018 | ilavu

Ray, Did you solve this problem? I am having same error on same model machine. My problem is, when camera axis moves to look at the first fiducial, camera hits to the cleaner and error comes up with rising table error, camera axis not home. Even log

DEK HORIZON 265 Squeege Pressure question

Electronics Forum | Thu Aug 27 09:29:04 EDT 2020 | serge_pirog

Yes, I calibrated the height, no error. How can I check that pressure was compensated? If we press button "continue" after some cycles of printing system will show "error".

DEK HORIZON 265 Squeege Pressure question

Electronics Forum | Thu Aug 27 03:19:21 EDT 2020 | dekhead

Have you done Squeegee Heights calibration? (no tools required) Does it complete cal routine without error? Does pressure compensate on next print, with corresponding squeegee, following acknowledgement of pressure error? The readings calibration, ge

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 03:32:46 EST 2018 | raymccomb

yes we resolved the engineer did not set the servo to zero so it did not know its datum start point.

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 12:02:28 EST 2018 | ilavu

Camera works fine from home to ref. position to fiducial1 and 2. Problem shows up from home to board stop. AC voltage between AC1 and AC2 is 41.7 and during move it drops to 41.5.

DEK HORIZON 265 Squeege Pressure question

Electronics Forum | Wed Nov 06 08:23:53 EST 2019 | dekhead

If it is always showing 5.0Kg as the "target" value on the error on the first print then yes there is a problem. Are you certain that it is accomplishing the requested (12Kg ?) on the prints thereafter? Does it do Heights calibration (no tools requir


dek 265 horizon fatal error searches for Companies, Equipment, Machines, Suppliers & Information

2024 Eptac IPC Certification Training Schedule

Software for SMT placement & AOI - Free Download.
thru hole soldering and selective soldering needs

Training online, at your facility, or at one of our worldwide training centers"
Sell Your Used SMT & Test Equipment

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
SMT feeders

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
Professional technical team,good service, ready to ship- Various brands pick and place machine!

Thermal Transfer Materials.