DEK 265 motor com error, axis 1,2,3 fatal error

Electronics Forum | Wed Aug 31 09:35:15 EDT 2016 | dekhead

Certainly possible CPU board issue; but check PC power supply, that all DCV are present and strong. www.dekhead.com

DEK 265 motor com error, axis 1,2,3 fatal error

Electronics Forum | Thu Sep 01 09:08:04 EDT 2016 | dekhead

Yes, wired correctly (5, 12, -12) can easily run on a standard 300W computer PSU.

DEK 265 motor com error, axis 1,2,3 fatal error

Electronics Forum | Fri Sep 02 04:18:48 EDT 2016 | bukas

i have tested voltages on Processor board X12. all voltages are ok and stabil but +VPP (PT8 - TP9), it reads 0 volts

DEK 265 motor com error, axis 1,2,3 fatal error

Electronics Forum | Wed Aug 24 05:23:45 EDT 2016 | bukas

hello, DEK wont start and im getting this error message: motor com error, axis 1,2,3 fatal error, reinitialise machine. this happens about 30 sec after BIOSes are copied to shadow ram. euro sys cards are inserted properly and on segment display is s

DEK 265 motor com error, axis 1,2,3 fatal error

Electronics Forum | Wed Aug 24 09:20:25 EDT 2016 | dekhead

Suspect comms link error from Y3 to Y1 crate. COM 2 off of CPU, depending on board. If CPU board has RS485 port it is direct to back panel of PC; if older board it only has RS232 and thus requires 232/485 converter board (internal to PC). then direct

DEK 265 motor com error, axis 1,2,3 fatal error

Electronics Forum | Thu Sep 01 08:30:54 EDT 2016 | bukas

Certainly possible CPU board issue; but check PC > power supply, that all DCV are present and > strong. > > www.dekhead.com > Certainly possible CPU board issue; but check PC > power supply, that all DCV are present and > strong. > > http:/

DEK 265 pneumatic power down error

Electronics Forum | Thu Jul 30 22:48:17 EDT 2020 | dekhead

MM (MultiMove) cards are in the M19, Motor Control, crate (located front of machine, right side). MM's are the larger cards located on the far right side; X11, X12 and X13 slots (X11 slot is only used in Infinity, empty slot on Horizon / ELA).

Dek 265

Electronics Forum | Mon Feb 02 11:51:54 EST 2004 | jsk

error code: motor comms failure.card3, Axis123 fatal error-reinitialize machine I swapped x3 and x4, and still get the same error. Any suggestion would be greatly appreciated Thanks in advance, jsk

DEK 265

Electronics Forum | Wed Dec 07 14:20:29 EST 2005 | Robert

I had a DEK 265LT with error code: motor comms failure.card 1, Axis123 fatal error-reinitialize machine during machine boost up I replaced new card 1 and still get the same error. Any suggestion would be greatly appreciated Thanks in advance, Rober

Dek 265

Electronics Forum | Wed May 03 08:43:51 EDT 2006 | Mark Fick

I have a DEK 265 with error code: motor comms failure.card 0, Axis123 fatal error-reinitialize machine during machine boost up I replaced new card 0 and still get the same error.I have tried to load the mint program but I cannot get program to abort


dek 265 horizon fatal error searches for Companies, Equipment, Machines, Suppliers & Information

Circuit Board, PCB Assembly & electronics manufacturing service provider

Wave Soldering 101 Training Course
pressure curing ovens

High Precision Fluid Dispensers


Best Reflow Oven
SMT feeders

World's Best Reflow Oven Customizable for Unique Applications