Electronics Forum | Fri Jan 17 11:55:58 EST 2020 | emeto
We don't have any of these. Our printers use the squeegee arm to detect and align stencil automatically.
Electronics Forum | Mon Jan 20 17:37:30 EST 2020 | sumote
Here is a picture of the inside of my machine. https://drive.google.com/file/d/1hsLLHz1ho867qcSf7AYUoivUUn8NFbH6/view?usp=sharing
Electronics Forum | Mon Jan 20 03:13:34 EST 2020 | silverlead
Included screenshots from DEK manual, outlining stencil depth adjustment. Basically, distance from rear of the stencil to the front of the image is value needed to be set on scale when positioning stencil. There is an other way to adjust stencil, by
Electronics Forum | Tue Jan 21 08:49:42 EST 2020 | emeto
I am sure you can upgrade it with DEK and it should not be so expensive. You can also ask them the price of the auto system. This is an arm(controlled by cylinder I think) and software to control it. This one moves the stencil in place when you load
Electronics Forum | Wed Dec 13 08:54:28 EST 2017 | raymccomb
We have a DEK 265 and we have fitted new belts to it after one split in use. when we set back up and run program A all is OK, when we go to run program B it has System Error. Servo Following Error - Fatal Error - Reinitialise machine. Does any one h
Electronics Forum | Mon Jan 20 17:26:07 EST 2020 | sumote
I see what the issue is now. A previous owner has removed the slider from the machine. I can see where it was mounted (bare metal where it was originally mounted as opposed to the black paint/powder coat). Is this slider available to purchase to re
Electronics Forum | Thu Jan 04 21:38:27 EST 2018 | dekhead
Error is occurring during move to fiducial 1 position (from board stop position)? Or during move to board stop position (from park position)? What is error displaying onscreen? Did you also just replace belt(s)?
Electronics Forum | Fri Jan 05 03:32:46 EST 2018 | raymccomb
yes we resolved the engineer did not set the servo to zero so it did not know its datum start point.
Electronics Forum | Fri Jan 05 12:02:28 EST 2018 | ilavu
Camera works fine from home to ref. position to fiducial1 and 2. Problem shows up from home to board stop. AC voltage between AC1 and AC2 is 41.7 and during move it drops to 41.5.
Electronics Forum | Wed Nov 06 07:27:47 EST 2019 | kylehunter
To do that requires a calibration scale, which we don't have. But even if it is out of calibration, it still wouldn't explain why it states that the setpoint is 5kg always, even when it is set to 12kg.