Electronics Forum | Wed Dec 07 22:39:03 EST 2005 | Alan

Robert, you will have to re-load the MINT software. It only takes a couple of minutes to do this. This will fix out the errors. Refer to your DEK manuals on how to carry out this function. Cheers, Alan.

Dek 265

Electronics Forum | Fri Nov 04 11:09:46 EST 2005 | moonshine

I concur with other advice. Visit http://www.moonmanondarkside.com for much more information and free operational procedures, from the POD ftp site, for this venerable machine. MoonMan

DEK 265 vision alignment...

Electronics Forum | Thu Feb 13 10:38:33 EST 2003 | vortex

While trying to develop new programs for our DEK Horizon 265 we are forced to use pads as vision alignments due to lack of real fiducals, thanks engineering. My question is, Is there any way to narrow the search window when performing a locate fiduca

DEK 265 Horizon

Electronics Forum | Sun May 04 19:18:42 EDT 2008 | dman97

Hi all, I recently acquired a year 2000 dek 265 horizon. It has a manual screen loader with that stupid hand crank adjustable stopper. Can anyone tell me how I am supposed to measure the stencil image dimensions for a front justified stencil? Now on

DEK 265 Printer Error

Electronics Forum | Tue May 27 15:11:13 EDT 2014 | dekhead

1. Rising Table Position error is, most commonly an issue of motor movement or sensor(s); Not receiving an expected input (sensor input / 'DONE' signal) in expected period of time. Try homing table in Diagnostics see if it moves and what movements ar

DEK 265 to DEK Horizon 2 question

Electronics Forum | Mon Jan 20 03:13:34 EST 2020 | silverlead

Included screenshots from DEK manual, outlining stencil depth adjustment. Basically, distance from rear of the stencil to the front of the image is value needed to be set on scale when positioning stencil. There is an other way to adjust stencil, by

DEK 265 Horizon - Calibration Procedure

Electronics Forum | Tue Jun 03 20:09:31 EDT 2008 | fastek

Look in your manual. There are also calibration stencils and boards necessary to calibrate DEK printers. Do you have them? If not I might have a set I would sell.

DEK 265 GSX air conditioner refrigerant pressure

Electronics Forum | Fri Apr 27 02:17:37 EDT 2018 | bukas

hello everyone, I have issue with one of my DEK air conditioners, it starts to freeze soon after we turn it on. most probable cause is low air flow or low refrigerant pressure. does anyone know what is operating refrigerant pressure range for DEK ai

DEK 265 to DEK Horizon 2 question

Electronics Forum | Mon Jan 20 17:26:07 EST 2020 | sumote

I see what the issue is now. A previous owner has removed the slider from the machine. I can see where it was mounted (bare metal where it was originally mounted as opposed to the black paint/powder coat). Is this slider available to purchase to re

DEK HORIZON 265 Squeege Pressure question

Electronics Forum | Wed Aug 26 18:36:17 EDT 2020 | serge_pirog

Hello. Could I ask you for help. We have DEK Europa. We have changed ProFlow to squeegee head with feedback. After this during solder paste printing system shows the difference between set pressure (9 kg) and real pressure (7,5kg). I have read manual