Electronics Forum | Sat Sep 22 13:02:40 EDT 2012 | elefu
Dek265 Upward vision is dim. Replaced bulb. Vision is still to dark to see anything. Bottom you can see fine. Any ideas?
Electronics Forum | Wed Dec 07 14:20:29 EST 2005 | Robert
I had a DEK 265LT with error code: motor comms failure.card 1, Axis123 fatal error-reinitialize machine during machine boost up I replaced new card 1 and still get the same error. Any suggestion would be greatly appreciated Thanks in advance, Rober
Electronics Forum | Mon Feb 02 11:51:54 EST 2004 | jsk
error code: motor comms failure.card3, Axis123 fatal error-reinitialize machine I swapped x3 and x4, and still get the same error. Any suggestion would be greatly appreciated Thanks in advance, jsk
Electronics Forum | Wed Dec 07 22:39:03 EST 2005 | Alan
Robert, you will have to re-load the MINT software. It only takes a couple of minutes to do this. This will fix out the errors. Refer to your DEK manuals on how to carry out this function. Cheers, Alan.
Electronics Forum | Fri Feb 19 09:34:27 EST 2010 | baildl632
Thanks for the support. Maybe you can help me with another problem. I get a pate dispensor error command time out, which clears itself, then a screen actuator error command time out that doesn't clear during initialisation. Machine won't do anything
Electronics Forum | Wed May 03 08:43:51 EDT 2006 | Mark Fick
I have a DEK 265 with error code: motor comms failure.card 0, Axis123 fatal error-reinitialize machine during machine boost up I replaced new card 0 and still get the same error.I have tried to load the mint program but I cannot get program to abort
Electronics Forum | Mon Feb 02 14:30:32 EST 2004 | kauer
Could be an intermitant card, or encoder issue. Sounds like the machine is giving this error because it is loosing track of one of the axis and instead of trying to move something and possibly crash, it locks up in error mode. Could be something as s
Electronics Forum | Mon Feb 02 14:06:27 EST 2004 | jsk
I did reload mint. When i do this the machine runs fine for about 15 minutes, but i have to continue loading boards. If I let the machine idle for 3-5 minutes, i get the error. We are a low volume manufacturing company, so on a 20 piece run i will re
Electronics Forum | Mon Sep 19 11:29:33 EDT 2011 | padawanlinuxero
Hello guys ! I have a problem with a DEK 265 GSX, sometimes after download the vision or during, I get this error message: Vision hardware error Controlled lighting not responding FATAL ERROR - REINITIALISE MACHINE Now for a few weeks it gave me
Electronics Forum | Sun Nov 24 15:01:09 EST 2019 | dekhead
dekhead@att.net
Industrial Sensor Vision International specializes in advanced camera technology of high resolution fast speed cameras for automation, AOI, 2-D/3-D, SPI inspection and wafer inspection.
3 Morse Road 2A
Oxford, CT USA
Phone: +1 203 592 8723